Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 43
All manuals and user guides at all-guides.com

5. Technical Data

Device class:
Multiple of the limit value (LV5):
Nominal minimum volume flow
Air quantities
1
:
Level 1
Level 2
Level 3
Level 4
Carrying belt adjustment :
Range, Battery Life
1, 2
:
Level 1
Level 4
Battery charge time
1, 3
:
Battery capacity
1, 3
:
Battery voltage
1, 3
:
Battery charge cycles
1, 3
1, 4
Noise level
:
Application temperature:
Application Humidity:
Weights
1
:
Blower unit with filter, battery
and carrying belt:
Protective screen with diffuser face cover
and automatic filter:
Particle filter:
Battery:
Charger:
Connecting hose:
Approximate values, some depend on air density, temperature, etc.
1
Measured with new filter without dust impact and conditioned battery. In practice values differ
2
because the filter is impacted by dust and every battery loses capacity over the course of its life.
Depends on age, condition, and previous charge cycles.
3
Measured at a distance of one meter away from the blower unit.
4
The noise level depends on the surroundings.
LVs are, for example, the limit values listed in TRGS 900 for air at the workplace-
5
MWC and TGC values (MWC = Maximum Workplace Concentration;
TGC = Technical guideline concentration).
1
:
:
TH2 P
20
160 l/min
170 l/min
185 l/min
195 l/min
210 l/min
approx. 80 cm to 150 cm
495 min (8,25 hrs)
330 min (5,5 hrs)
7 hrs
4.500 mAh
7,2 V
500
52 dB(A)
0°C to +40°C
< 80% relative humidity
1.480 g
700 g
65 g
485 g
275 g
100 g
EN
41

Publicité

Table des Matières
loading

Table des Matières