Honeywell HE360 Instructions D'installation page 4

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

HE360 HUMIDIFIER AND INSTALLATION KIT
Fig. 6. Installing the saddle valve.
3. Use 1/4 in. (6 mm) OD tubing and connect the sad-
dle valve to the inlet side of the solenoid valveon
the humidifier (see Fig. 7).
a. Place the brass compression nut over the
tubing.
b. Install brass insert into end of tubing.
c. Slide the plastic compression ring over the
tubing. (Discard copper compression ring pro-
vided with valve.)
NOTE: To prevent leaking, use plastic (Delrin) sleeve
rings with plastic tubing. Use copper sleeve
rings only with copper tubing.
d. Insert the tubing into the solenoid valve fitting
and support the valve while tightening the com-
pression nut.
NOTE: Do not over-tighten the compression nut. Mod-
erate tightness prevents leaking.
e. Repeat steps a. through d. for solenoid valve
fitting.
f.
Secure tubing with clamps provided.
BRASS COMPRESSION NUT
Fig. 7. Installing feed tubing.
4. Connect a 1/2 in. (13 mm) drain tube to the humid-
ifier drain fitting and run to the floor drain (see Fig.
8).
a. Slide the drain clamp over the tubing.
b. Push the tubing over the drain nipple on the
humidifier.
69-1646EF—01
SCREW DRIVER
WATER LINE
M20175
PLASTIC
COMPRESSION RING
BRASS INSERT
M20176
c. Hand-tighten the clamp around the tubing to
secure the humidifier drain.
d. Fasten the drain tubing (can use duct tape)
along the route to prevent movement and
ensure downward slope for correct drainage.
NOTE: Cut tubing to correct length so the tubing termi-
nates at the drain.
Fig. 8. Installing the drain tubing.
Installing the Sail Switch
Adapting Switch to Air Flow Direction
The S688A Sail Switch has two counterbalancing springs
in place as shown in Fig 9. These springs offset the effect
of gravity for air flow direction.
IMPORTANT:
Do not use the sail switch with both springs
attached. Be sure to select air flow direction and
remove spring(s) not required for installation.
Fig. 9. Adapting sail switch to air flow direction or
mounting position.
4
M20177

Publicité

Table des Matières
loading

Table des Matières