Bosch LWPS 3 Instructions D'installation Et D'utilisation page 45

Publicité

Les langues disponibles

Les langues disponibles

LWPS 3 - LWPS 14
6.8
Nominal current at A7/W35 / cos 
6.9
Nominal power consumption A2 / W35
6.10 Power consumption of compressor protection
(per compressor)
6.11 Power consumption of fan
7
Complies with the European safety regulations
8
Additional model features
8.1
Type of defrosting
8.2
Condensate tray frost protection /
Water in device is protected from freezing
8.3
Max. operating overpressure (heat source/heat sink)
9
Heat output / coefficients of performance (COP)
5
9.1
Heat output / COP
9.2
Cooling capacity / COP
1. The specified sound levels apply if the supporting feet (available as an option) are not used. If the supporting feet are used, the level can increase by up to 3 dB (A).
2. The specified sound pressure level corresponds to the operating noise of the heat pump in heating operation at 35°C flow temperature.
The specified sound pressure level is the free sound area level. The measured value can deviate by up to 16 dB(A) depending on the installation location.
3. Please note that additional space is required for pipe connections, operation and maintenance.
4. Factory default 6 kW
5. These data indicate the size and capacity of the system according to EN 14511. For an analysis of the economic and energy efficiency of the system, the bivalence point and
the regulation should be taken into consideration. These figures are only achieved with clean heat exchangers. Instructions for care, commissioning and operation can be found
in the relevant sections of the installation and operation instructions. The specified values have the following meaning, e.g. A7 / W35: Heat source temperature 7 °C and heating
water flow temperature 35 °C.
6. Maximum heating/cooling output
7. Max. intake incl. pipe heating and immersion heater (state of supply)
8. See CE declaration of conformity
9. The heat circulating pump and the heat pump controller must always be ready for operation.
10.COP-optimised operation
www.boesch.at
A / --
6
W
W
9
bar
10
at A-15 / W35
kW / ---
6
kW / ---
10
at A-7 / W35
kW / ---
6
kW / ---
10
at A-7 / W55
kW / ---
6
kW / ---
10
at A2 / W35
kW / ---
6
kW / ---
10
at A7 / W35
kW / ---
6
kW / ---
10
at A7 / W45
kW / ---
6
kW / ---
10
at A7 / W55
kW / ---
6
kW / ---
10
at A10 / W35
kW / ---
6
kW / ---
10
at A20 / W35
kW / ---
6
kW / ---
10
at A20/ W55
kW / ---
6
kW / ---
6
at A27 / W7
kW / ---
6
at A27 / W18
kW / ---
6
at A35 / W7
kW / ---
6
at A35 / W18
kW / ---
452162.66.16a · FD 0108
2.8 / 0.99
5.14 / 0.99
0.8
1.41
--
--
43
124
8
8
Reverse circula-
Reverse circula-
tion
tion
No / Yes
No / Yes
3.0
3.0
EN 14511
EN 14511
2.3 / 2.1
3.6 / 2.3
2.3 / 2.1
3.6 / 2.3
2.5 / 2.6
4.2 / 2.8
2.5 / 2.6
4.2 / 2.8
2.0 / 1.7
2.9 / 1.8
2.0 / 1.7
2.9 / 1.8
2.6 / 3.2
4.8 / 3.4
2.6 / 3.2
4.8 / 3.4
3.0 / 4.6
5.6 / 4.8
3.0 / 4.6
5.6 / 4.8
2.8 / 3.2
5.4 / 3.4
2.8 / 3.2
5.4 / 3.4
2.5 / 2.6
5.1 / 2.9
2.5 / 2.6
5.1 / 2.9
3.2 / 4.8
6.0 / 5.1
3.2 / 4.8
6.0 / 5.1
3.6 / 4.0
7.3 / 5.8
3.6 / 4.0
7.3 / 5.8
2.2 / 3.1
5.7 / 3.4
2.2 / 3.1
5.7 / 3.4
2.4 / 3.8
6.5 / 3.3
3.2 / 4.6
8.7 / 4.2
2.3 / 3.0
6.2 / 2.6
3.0 / 4.0
9.0 / 3.4
English
9.27 / 0.99
4.94 / 0.99
1.91
3.50
--
--
124
248
8
8
Reverse circula-
Reverse circula-
tion
tion
No / Yes
Yes/ Yes
3.0
3.0
EN 14511
EN 14511
5.2 / 2.3
10.6 / 2.4
5.2 / 2.3
10.8 / 2.4
6.3 / 2.4
13.9 / 2.9
6.3 / 2.4
13.9 / 2.9
4.2 / 1.7
11.3 / 2.1
4.2 / 1.7
11.3 / 2.1
5.3 / 3.6
10.5 / 3.6
6.2 / 3.2
11.0 / 3.2
5.6 / 4.8
10.6 / 4.1
9.0 / 4.3
14.7 / 4.3
5.4 / 3.4
9.8 / 3.7
8.3 / 3.3
13.9 / 3.3
5.1 / 2.9
8.8 / 2.9
6.2 / 2.6
13.2 / 2.7
6.0 / 5.1
11.3 / 4.5
9.6 / 4.5
15.7 / 4.3
7.3 / 5.8
13.9 / 5.5
10.8 / 5.3
22.3 / 5.1
5.7 / 3.4
10.8 / 3.8
8.4 / 3.2
16.2 / 3.6
6.5 / 3.3
12.9 / 3.0
8.7 / 4.2
17.1 / 3.7
6.2 / 2.6
12.3 / 2.5
9.0 / 3.4
15.5 / 3.3
EN-19