1. TECHNICAL DATA

As a stove of construction type 1, it is possible to connect it to the chimney together with an existing other stove or another
hearth for solid fuels (multiple use), as long as the chimney dimensioning complies with DIN 4705-3.
EXHAUST VALUES
for multiple use of the chimney and for the calculation of the
chimney measurements
Fluegas mass flow
Fluegas temperature
Minimum feed pressure
Nominal thermal output

2. IMPORTANT INFORMATION

The installation and operation information given here is of
general nature. National and European standards, local and
building regulations as well as fire prevention laws must be
observed during the operation of the stove.
General safety instructions for the
operation of your stove
Read the entire manual before starting up your stove
thoroughly and observe the caution notices.
Your heating unit must not be moved without approved
means of transport with sufficient load-bearing capacity.
Your heating unit is not suitable to be used as a stand or
as a ladder.
Please keep in mind that your stove's surface heats up
considerably during operation. We therefore recommend
wearing a safety mitten (included in the delivery) when
operating your stove. Make your children aware of this
particular danger and keep them at a distance from the
heating unit whenever it is in operation.
Only burn approved fuels and materials as listed in the
chapter "Clean Burning".
Rubbish must not be used as heating material!
The burning or placing of flammable or explosive
materials, like empty spray cans, etc. into the firebox as well
as the storage of such materials in the immediate vicinity of
your heating unit is strictly forbidden due to the danger of
explosion.
Do not wear loose or flammable clothing when adding fuel
to the fire.
Placing non-heat-resistant objects on the heating unit or
in the vicinity of the heating unit is forbidden.
Do not lay laundry onto the stove for drying. Laundry hung
up to dry must be kept at a safe distance from the stove
because of the danger of fire.
(acc. to DIN 4705-2 & -3)
7,8
[g/s]
257
[°C]
]
12
[Pa
[ Pa]
10
at 0.8 times nominal
thermal output
5
TECHNICAL DATA
Height
Width
Depth
Weight
Flue pipe outlet-Ø
Nominal thermal output
Maximal thermal capacity
Minimal heating capacity
Room heating capacity
(depending on building insulation)
This stove is tested as a "Zeitbrand-Feuerstätte"
(intermittent burning device), which means that a continual
operation can only be achieved by a constant putting more
wood on fire.
During the operation of your heating unit it is forbidden to
use flammable or explosive materials in the same or an
adjacent room to the one in which your heating unit is located.
The appliance must be operated with the stove door
closed.
The stove door and all fittings for adjusting the stove must
be closed, if the appliance is out of use.
Attention – stove varnish is no rust prevention!
Setting up your stove
Required safety distances
(Minimum distances – see name plate)
see Fig. 2
a > 800 mm – towards the front in the radiated area
b > 200 mm – to the side in the radiated area
c > 200 mm – to the back
Make sure that the room in which the stove is set up has at
least one door or window into the outside or is directly
adjacent to such a room. Other fireplaces and extractor
hoods must not be operated in the same room as the stove.
Floor load capacity
Make sure that the load capacity of the supporting
construction is sufficient to carry the weight of the entire unit,
before the heating unit is installed.
www.austroflamm.com
CODY
Cody
Cody
[mm]
850
[mm]
800
[mm]
431
[kg]
185
[mm]
130
[kW]
8,0
[kW]
9,0
[kW]
3,5
[m³]
82 - 210
5