Application Area; Instructions And Technical Norms - hajdu HB300 Manuel De Mise En Service, D'opération Et D'entretien

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 133
____________________________________________EN________________________________________7
o
COP 15/10-55
C
EN-255-3
COP 7/10-55°C
EN-16147
Noise level
Type of outlet air
Heatable volume
Voltage/frequency
Fuse
Rated heating performance
Largest electric power consumption
Heating time
Max. water temperature
Min. Water temperature
Heat insulation/thickness
Tank
Pipe coal
Corrosion protection
Active anode maintenance
Built-in controller
Electric wiring
Protection degree
Touch protection to be applied
It can be connected to electric system supplied with protective earthing as defined in
Regulations on the product:
Storage and transportation requirements
Quality certification
Quality
HAJDU Hajdúsági Industrial Closed Company Limited by Shares (HAJDU Hajdúsági Ipari Zrt) as
manufacturing company hereby certifies that the appliance comply with the technical features
described in the quality certification label.
2.2.

Application area

The appliance produces domestic hot water or hot water of similar usage at temperature under
the boiling point. For this aim, the appliance must be hydraulically connected to the domestic water
pipeline. Electric current is also required for the operation of the appliance. The usage of air ducts is
optional and it will be described later in details.
It is forbidden to use the appliance for purposes other than the pre-defined ones. Any other
usage of the appliance is considered to be improper and therefore forbidden. The appliance must not
be used especially in environments exposed to industrial cycles and / or corrosive or explosive
materials.
The manufacturer and distributor shall take no responsibility for damages raised by inefficient
installation, improper or wrong usage, rationally not foreseen usage or incomplete or careless
compliance of manual instructions.
2.3.

Instructions and technical norms

Persons with reduced physical, perceptive or mental abilities (including children) or persons
without complete knowledge and experience on the appliance are not permitted to use the appliance,
except for the person responsible for their safety ensures supervision or adequate information on the
All manuals and user guides at all-guides.com
Electric heating
Others
Table 2.10.-1.
≥3,5
≥2,1
48 dB(A)
Air support flowing vertically upward
100 l
L/N/PE 230V~ / 50Hz
5A/250V~(T)
1800W
16 A
3,5 h
60
o
C
o
10
C
Freon free PUR insulation / 50 mm
Enamelled steel sheet
Enamelled steel pipe
Enamel + active anode
Anode consumption display
Electric heating and temperature controlling
device
Fixed
IPX1
Touch protection class I.
EN 60335-1
EN 60335-2-21
EN 14511-3
EN 16147:2011
IEC 721-3-1 IE12
IEC 721-3-2 IE22
CE, NF Performance Cat.2 indication, CPT
Ist class
IEC 6036
.

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Hb300c

Table des Matières