HI mode:
The heater is
working at
highest wattage.
3, Choose the operating temperature
When the heater operated at "HI", "MED" or "LO" mode, by pressing the " " or" " button you
can set the operating temperature from 5℃-35℃. Each effective pressing comes with a sound of
buzzer and makes the operating temperature change by 1 . When the ambient temperature is
higher than the set operating temperature, the heater will stop work; When the ambient
temperature is lower than the set operating temperature, the heater will start work.
Note: Regardless of the ambient temperature, the heater always operates at the mode you set
for 2 minutes at first

4, Time function

1) When the heater is at STANDBY mode, you can set when the heater can start work.
When you press the "TIMER" button, the figure is o and the letter "H" will lighten which indicates
the hours.
All manuals and user guides at all-guides.com
Auto mode:
1, when the ambient temperature is less than 22ºC, the
heater operates at High setting;
2, when the ambient temperature is more than 22 ºC and
less than 25 ºC, the heater operates at MED setting;
3, when the ambient temperature is more than 25 ºC and
less than 28 ºC, the heater operates at LO setting;
4, when the ambient temperature is more than 28 ºC, the
heater operates at STAND BY mode (no power input).
MED mode:
The heater is
working at
middle wattage.
- 45 -
LO mode:
STANDBY
mode:
The heater is
working at
The heater
lowest wattage.
doesn't work.