Hamilton Beach Commercial HVS400 Mode D'emploi page 9

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

8. Press down on the Vacuum Lid Handle to form a tight seal.
9. Press the "START" Button to initiate the vacuuming process (the
"VACUUM" Light will illuminate). Release the Vacuum Lid Handle at the
first sign of bag collapse. The Vacuum Sealer will automatically seal the
bag when a preset vacuum pressure is reached in the Vacuum Chamber.
Sealing lasts for 3 seconds (the "SEAL" Light will illuminate).
10. To manually seal a bag, press the "MANUAL SEAL" Button at any time
during the vacuuming process.
11. You can stop the vacuuming process at any time by pressing the "STOP"
Button.
12. Sealing is complete when the Vacuum Chamber releases after a
3-second cooling period (the "COOL" Light will illuminate). The release is
audible.
13. Open the Vacuum Lid and remove the bag. Wait at least 20 seconds
before sealing another bag to avoid overheating the unit.
14. Turn the Vacuum Sealer "OFF" ( ) and unplug the Power Cord when you
are done.
PREPARING VACUUM BAGS FROM A ROLL
1. Make sure the Vacuum Sealer is in the "OFF" ( ) position. Attach the
Power Cord and plug into the electrical outlet.
2. Turn the Vacuum Sealer "ON."
3. The "POWER" Light on the display and "POWER INDICATOR" Switch will
illuminate, and the Internal Cooling Fan will run.
4. Open the Vacuum Lid.
5. Cut a vacuum bag to the length you want from a roll.
6. Place either open end of the bag against the outer face of the Oval
Vacuum Chamber Seal in the Vacuum Chamber.
7. Close the Vacuum Lid. The bag end should be sandwiched between the
Vacuum Lid Seal and Seal Bar Heating Element. Make sure there are no
wrinkles or creases in the bag in the sealing area.
8. Press and hold the Vacuum Lid Handle down. You may need to continue
holding the bag.
9. Press the "START" Button (this will engage the Pump and the Heating
Element). Press the "MANUAL SEAL" Button to seal the vacuum bag.
10. Sealing is complete when the Vacuum Chamber releases after a
3-second cooling period (the "COOL" Light will illuminate). The release is
audible.
11. Open the Vacuum Lid and remove the bag. DO NOT try to open the
Vacuum Lid before the vacuum has released, or unit damage may occur.
Wait at least 20 seconds before sealing another bag to avoid overheating
the unit.
12. Turn the Vacuum Sealer "OFF" ( ) and unplug the Power Cord from the
electrical outlet.