F200 CHARGED-MEDIA AIR CLEANER
SPECIFICATIONS
IMPORTANT
The specifications in this publication do not include
normal manufacturing tolerances; therefore, an indi-
vidual unit may not exactly match the listed specifica-
tions. This product is tested and calibrated under
closely controlled conditions, and some minor differ-
ences in performance can be expected if those con-
ditions are changed.
Model:
F200E Charged-Media Air Cleaner includes a cabinet, access
door and pleated media filter, and an RF AIRWATCH®
Indicator.
Application:
Use with gas, oil, and electric forced warm air furnaces and
with compressor cooling. Can be used with heat pumps if filter
is changed regularly to prevent excessive pressure drop.
Efficiency:
Efficiency Ratings: Based on American Society of Heating,
Refrigerating and Air-Conditioning Engineers Standard 52.2-
1999. Efficiency ranges are defined for small particles, E1=0.3
to 1.0 microns; medium particles, E2=1.0 to 3.0 microns; and
large particles, E3=3.0 to 10.0 microns.

ORDERING INFORMATION

When purchasing replacement and modernization products from your TRADELINE® wholesaler or distributor, refer to the
TRADELINE® Catalog or price sheets for complete ordering number.
If you have additional questions, need further information, or would like to comment on our products or services, please write or
phone:
1. Your local Honeywell Automation and Control Products Sales Office (check white pages of your phone directory).
2. Honeywell Customer Care
1885 Douglas Drive North
Minneapolis, Minnesota 55422-4386
3. http://customer.honeywell.com or http://customer.honeywell.ca
In Canada—Honeywell Limited/Honeywell Limitée, 35 Dynamic Drive, Toronto, Ontario M1V 4Z9.
International Sales and Service Offices in all principal cities of the world. Manufacturing in Australia, Canada, Finland, France,
Germany, Japan, Mexico, Netherlands, Spain, Taiwan, United Kingdom, U.S.A.
68-0238EF—04
Initial Efficiency:
E1=64%
E2=91%
E3=99%
Minimum Efficiency Reporting Valve (MERV): 13 at 492 fpm.
Filter Media: Pleated for greater media capacity.
Filter Element: Underwriters Laboratories, Inc.: UL 900,
Class 2 Listed.
Pressure Drop: See Fig. 3.
Initial Pressure Drop: 0.31 in. wc at 492 fpm.
Temperature Rating: -40° to +140°F (-40° to +60°C).
Dimensions: See Fig. 1.
Mounting:
Mounts in any position in the return air duct, usually next to
the furnace blower compartment. Cabinet is sturdy enough to
support weight of a residential furnace and evaporator coil.
Upgrade Path:
The F200 uses the same cabinet as the F300 Electronic Air
Cleaner. Upgrade may require installing the cell key,
electronic cells, protective screens and installation and wiring
of the power box, depending on model.
2

Publicité

Table des Matières
loading

Table des Matières