Electrical connection

NOTE
All electrical connections must be carried out by
an authorised electrician.
Electrical installation and wiring must be carried
out in accordance with the stipulations in force.
The heat pump/indoor module must not be
powered when installing RMU 40.
Connecting communication and power supp-
ly
RMU 40
+12V GND
B
A
F1145/F1245/F370/F470/F750/VVM500
The terminal block in RMU 40 is connected to terminal
block X4:9–12 on the input card (AA3) in the heat
pump/indoor module.
Use cable type LiYY, EKKX or similar.