Télécharger Imprimer la page

Empire Comfort Systems DVCC32BP7-3 Manuel D'instructions page 2

Publicité

Les langues disponibles

Les langues disponibles

GAS INPUT FOR DIRECT VENT FIREPLACE INSERT
CONVERTED TO PROPANE GAS:
DVC(C,P)32BP7 - 22,000 BTU per hour
DVC(C,P)36BP7 - 24,000 BTU per hour
DVC(C,P)42BP7 - 26,500 BTU per hour
The direct vent gas fireplace insert when converted to Propane
Gas will have a manifold pressure approximately 10.0" w.c.
(2.49 kPa) at the valve outlet with the inlet pressure to the valve
from a minimum of 10.8" w.c. (2.68 kPa) for the purpose of input
adjustment to a maximum of 14.0" w.c. (3.48 kPa).
INSTRUCTIONS FOR CONVERSION
1. If the fireplace is installed, turn OFF gas and electric supply
to fireplace before making gas conversion.
2. Remove bottom panel, grasp panel, lift and pull forward.
3. Release two glass frame spring clamps at bottom of firebox.
4. Remove glass frame assembly.
5. Remove logs from burner assembly.
6. Remove (2) 10 x 1/2" screws from rear log support. Remove
log support.
7. If applicable, remove liners and burner cover.
8. Remove four (4) 10 x 1/2" screws from burner. Grasp
burner assembly, lift and pull to the right to remove burner
assembly.
9. Use a 3/8" and 1/2" wrench to remove burner orifice.
10. Remove Natural Gas main burner orifice from orifice fitting.
11. Install Propane Gas main burner orifice into orifice fitting:
for DVC(C,P)32BP7 USE ORIFICE MARKED #54
for DVC(C,P)36BP7 USE ORIFICE MARKED 1.45 mm
for DVC(C,P)42BP7 USE ORIFICE MARKED 1.55 mm
12. Pull upward on pilot hood to remove and gain access to pilot
injector orifice.
13. Remove Natural Gas pilot injector orifice from pilot burner
with 5/32" hex (Allen) wrench.
14. Insert Appropriate Propane Gas pilot injector orifice into
pilot burner using the 5/32" hex wrench.
15. Re-install pilot hood to pilot assembly. Push downward to
snap in place.
Page 2
16. Convert the gas valve as instructed in S.I.T. Propane Gas
17. Align burner assembly with the air shutter as you place
18. Adjust air shutter setting to FULL Open on all models.
19. Attach burner assembly with four (4) 10 x 1/2" screws from
20. Attach rear log support with (2) 10 x 1/2" screws from Step 7.
21. The converted fireplace must be connected to a supply of
22. Refer to Log and Ember Placement in your Installation
23. The fireplace must be checked to ensure it is operating at
24. Replace glass frame onto firebox.
25. Secure the two glass frame spring clamps at bottom of
26. Replace bottom panel.
27. Gas conversion is completed.
The main burner flame and pilot burner flame must be checked
for proper flame characteristics, as outlined in the Installation
Instructions and Owner's Manual.
VERIFYING INPUT RATE OF CONVERTED FIREPLACE
The input of the fireplace must be checked as follows:
1. Turn off all other gas appliances. Clock the gas meter and
2. 3600 ÷ time (in seconds) = cu. Ft. per hour.
3. Then cu. Ft. per hour x heating value of gas = input rate
If fireplace is not installed or warranty card has not been returned
to Empire Comfort Systems, Inc., check off type of gas converted
to on card. Also, indicate conversion by adding "Conv." behind
type of gas.
Empire Comfort Systems Inc.
Belleville, IL
If you have a general question
about our products, please e-mail
us at info@empirecomfort.com.
If you have a service or repair
question, please contact your dealer.
www.empirecomfort.com
Valve Conversion Kit.
burner assembly into the original position in firebox.
Step 8.
the conversion gas and checked for leaks at all connections.
Intructions and Owner's Manual to place logs onto burner
assembly.
the correct pressure of 10.0" w.c.
firebox to secure glass door assembly.
determine the number of seconds required to consume one
cubic foot of gas.
(Btuh). On installation without gas meters, check manifold
for proper pressure.
41319-1-0220

Publicité

loading

Ce manuel est également adapté pour:

Dvcc32bp7-4Dvcp32bp7-3Dvcp32bp7-4Dvcc36bp7-3Dvcc36bp7-4Dvcp36bp7-3 ... Afficher tout