2.10 Controlling temperature
The supply temperature (probably lower in winter) and
pressure fluctuations can influence the temperature of the
water leaving the tap.
Turn the valve slowly in the closed direction for higher
temperatures (F1).
Add cold water for lower temperatures (F2).
Electrical connection (Fig. 5)
2.11 TR4000 5 ET, TR4000 6 ET, TR4000 6 EB,
TR4000 8 ET and TR4000 8 EB
(fixed electrical connection)
Connect the appliance on the terminal strip in accordance
with the connection schematic.
Put on the housing cover and push it onto the rear wall of
the appliance so that the upper and lower latches engage.
2.12 TR4000 4 ET and TR4000R 4 ET
Replacing the Power Supply Cord:
The power supply cord must be replaced by our customer
service only in order to avoid a hazard. The mains plug must
be pulled before replacing.
2.13 For all appliances
Vent the continuous-flow heater: Fully open the warm water
tap and flush out the appliance for about 1 minute (G), until
bubbles no longer emerge.
G
3

After installation

3.1
TR4000 5 ET, TR4000 6 ET, TR4000 6 EB,
TR4000 8 ET and TR4000 8 EB
(fixed electrical connection)
Switch on the fuses.
3.2
TR4000 4 ET and TR4000R 4 ET
Insert the plug into the mains socket.
TR4000 | TR4000R – 6 720 876 021 (2019/06)
All manuals and user guides at all-guides.com
1 min
First start-up (Fig. 6)
3.3
Initial rinsing
Open the warm water tap and allow water to flow for at least
1 minute (flow-rate at least 2 litres per minute). Only then
(for safety reasons) will the appliance begin to heat.
Info: The appliance will not heat if the dispensed water flow is
interrupted prematurely. Open the warm water tap again and
allow water to flow for at least 1 minute.
Tip: Should the appliance not start because of a reduced flow-
rate, remove the perlator, aerator or similar before starting and
repeating the process.
Important: If the continuous-flow heater does not have
sufficient water flow due to low water line pressure in your
domestic plumbing system:
Switch off the circuit-breakers/fuses or remove the mains
plug.
Remove the flow-rate limiter (H1–H4).
3.4
Controlling temperature
The supply temperature (probably lower in winter) and
pressure fluctuations can influence the temperature of the
water leaving the tap (see Fig. 4, left: pressurised [closed],
right: unpressurised [open]).
Turn the valve slowly in the closed direction for higher
temperatures (F1).
Add cold water for lower temperatures (F2).
Hand over the installation and operating instructions
to the user and explain how the appliance operates.
After installation