SYSTEM LAYOUT

A - IND4000V operator
B - Photocells (external)
C - Rack M4
D - Key selector
E - Tuned antenna
F - Flashing lamp
H - Galvanized column for photocells
I - Photocells (internal)
L - Safety edge fixed to column
M - Safety edge with wireless system

TECHNICAL FEATURES

Irreversible operating devices for sliding gates with a maximum weight of 4000 kg.
The irreversibility of this operating device allows you to avoid using any electric lock for
an effective closing of the gate. The motor is protected by an heat probe, that temporary
interrupts the operating cycle in case of prolonged use.
8/20

TECHNICAL DATA

Max. leaf weight
Thrust force to constant turns
Rack
Power supply
Power
Current absorbed
Capacitor
Daily operations suggested
Service
Unlocking device for
emergency manoeuvre
Working temperature
Protection
Limit switch
Measurements in mm
ITA
ENG
kg
W
µF
%
°C
IP
FRA
ESP
6-1624014
IND4000V
4000
N
3700
M4
230V 3~ 50/60Hz delta
connection (CT INVERTER)
380V 3~ 50/60Hz (CT3IND)
750
A
2,5
-
200
80
With key
-25 ÷ +70
54
Electromechanical
rev.3
19/01/2022