MOTOR AND RACK FITTING

Predispose a cable trunking in the holes.
Follow this procedure for the installation of the backing plate:
- Bend the brackets (Fig. 5).
- Make an excavation.
- Insert the cable trunking.
- Level and cement the fixing plate.
When the backing plate is fixed, open the front cover, remove the casing from the
motor by unscrewing the screws present in the lower part of the casing.
Place the motor on the fixing plate and screw with the M12 nuts supplied (Fig.5).
The rack shall be fitted over the motor support, at a certain distance from It.
Its height can be adjusted thanks to the holes In the rack.
The height adjusting is necessary to prevent the gate leaning on the driving gear
(Fig. 6).
To fix the rack on the gate, drill some Ø 5 mm holes and thread them using an
M6 screw tap.
The driving gear needs 2 or 3 mm clearance from the rack.

LIMIT SWITCH FITTING

In order to determine the gate travel length, place two cams at the ends of the
rack (Fig. 7).
Move the cams on the rack teeth to adjust their opening and closing travel.
To fix the cams to the rack, tighten the screws issued.

GROUND CONNECTION

The system must be grounded.
Check the presence of the connection inside the box near the motor (Fig. 8).
MAINTENANCE
To be carried out exclusively by skilled persons after the power supply to
the motor has been interrupted.
Periodically, when the gate is standstill, clean and keep the guide free from stones
and dirt.
10/20
Screw for fixing casing
Nuts
Brackets
Misure in mm
Ground
connection
ITA
ENG
FRA
ESP
Nuts
Backing plate
Holes for cables
6-1624014
rev.3
FIG. 5
FIG. 6
FIG. 7
FIG. 8
19/01/2022

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ind4000v/iInd4000v/t

Table des Matières