Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

TROUBLESHOOTING
PROBLEM
By giving a command with the remote control or
with the key selector, the gate doesn't open or the
motor doesn't start.
By giving a command with the remote control,
the gate does not open, but it works with the key
selector.
The gate starts, but stops immediately
GUARANTEE
In compliance with legislation, the manufacturer's guarantee is valid from the date stamped on the product and is restricted to the repair or free replacement of the
parts accepted by the manufacturer as being defective due to poor quality materials or manufacturing defects. The guarantee does not cover damage or defects
caused by external agents, faulty maintenance, overloading, natural wear and tear, choice of incorrect product, assembly errors, or any other cause not imputable
to the manufacturer. Products that have been misused will not be guaranteed or repaired. Printed specifications are only indicative. The manufacturer does not
accept any responsibility for range reductions or malfunctions caused by environmental interference. The manufacturer's responsibility for damage caused to
persons resulting from accidents of any nature caused by our defective products, are only those responsibilities that come under Italian law.

PRODUCT DISPOSAL

This product is an integral part of automation, and therefore must be disposed of together with it. As with installation operations, even at the end of the life of this
product, dismantling operations must be carried out by qualified personnel. This product consists of various types of materials: some can be recycled, others must
be disposed of. Find out about the recycling or disposal systems required by the regulations in force in your territory for this category of product.
WARNING! - certain parts of the product may contain pollutants or dangerous substances which, if dispersed in the environment, could have harmful effects on
the environment and human health.
As indicated by the symbol on the side, it is forbidden to throw this product into household waste. Then perform the "separate collection" for disposal, according
to the methods provided by the regulations in force in your territory, or return the product to the seller when buying a new equivalent product.
WARNING! - the regulations in force at local level may provide for heavy penalties in case of improper disposal of this product.
6-1624014
rev.3
230 volt mains voltage absent.
Emergency STOP present.
Fuse blown.
Power cable of motor not connected or faulty.
The photocell is not functioning or the beam is
interrupted.
The remote control has not been memorized or the
battery is flat.
The torque of the motor is insufficient.
The value of the obstacle sensitivity (if present) it is
not suitable for the installation.
19/01/2022
PROBABLE CAUSE
ITA
ENG
FRA
ESP
SOLUTION
Check the main switch.
Check for any STOP selectors or commands.
If not used, check the jumper on the STOP input of
the control unit.
Replace with one of same value.
Connect the cable to the appropriate terminal
board or replace it.
Check the connection, remove any obstacle across
the beam.
Carry out the remote control learning procedure on
the control unit or replace the battery with a new
one.
Modify the value of the torque in the control unit,
if possible.
Modify the value of the sensitivity in the control
unit, if possible.