Fault
Insufficient water
Crossflow, hot water being forced into
cold water pipe, or vice versa, when
mixer is closed
Spout temperature does not
correspond with temperature set
Temperature regulation not possible
Safety stop button not operating
English
Cause
- Supply pressure inadequate
- Regulator filter dirty
- Shower filter seal dirty
- filter insert shower dirty
- Backflow preventers dirty or leaking - Clean backflow preventers,
- Thermostat has not been adjusted
- Hot water temperature too low
- thermo cartridge calcified
- For new installations: basic body
incorrectly connected (should be:
cold right, hot left) or installed with
180º rotation
- Spring defective
- Button calcified
Assembly (see page 8)
Remedy
- Check water pressure (If a pump has
been installed check to see if the
pump is working).
- Clean filter in front of the mixer and
on the MTC-thermo cartridge
- Clean filter seal between shower
and hose
- Clean filter insert between shower
and hose
exchange if necessary
- Adjust thermostat
- Increase hot water temperature to
42 ºC to 60 ºC
- Exchange thermo cartridge
- Install function block turned through
180º
- Clean spring and/or button,
exchange if necessary
7