Even if the function was not concluded for some reason, there is
All manuals and user guides at all-guides.com
no fear of misuse: when time limit expires, the operation will be
automatically deactivated.
It is recommended that you add each stored finger to
the list of administrators and users. If the same fin-
ger of one user is stored more than once, each time it
should be enrolled separately, because the device re-
cords these as different entries. When deleting a user,
you need to delete each finger as many times as it was
saved. On the list you add the user's/administrator's
name, the date of enrolment, which finger is enrolled
and how many times.

3. REMOTE CONTROL

Enclosed to Bioreader is 1 remote control operating on 433 MhZ
frequency and communicating with the fingerprint reader over
encrypted connection with the so called 'rolling code' , which
changes every time when a remote button is pressed. Several
million different codes are stored in the remote control and
the reader, and when all are used, they are reused again. The
codes are interchanged according to a key known only to the
manufacturer.
The remote control range is only about 10cm, because the
fingerprint reader is in metal casing which impedes the signal.
Remote control has 4 buttons: A, B, C and D. Every button has its
function; they are described in the following section.
Remote control and fingerprint reader must be paired. This is
done in the manufacturing process.. If an additional remote
control is needed, this can be done according to the procedure
described below.
Adding a new remote control:
On the internal unit, you press the reset button for 10 seconds.
After 10 seconds, the fingerprint reader starts to emit audible
signal every second. You have 10 seconds. In this time you have
to press one of the buttons on remote control, which has to be
within 10cm from the fingerprint reader. The fingerprint reader
then emits a short beep and the green LED flashes for 1 second.

4. CHOOSING THE RELAY

The device has 2 in-built output relays, so that with one finger-
print reader you can open two doors or a door and another de-
vice of your choice (e.g. an alarm). When you store a fingerprint
you should also choose a relay which will be triggered by this
fingerprint. You do that when you add a fingerprint to the data-
base, so that you press an adequate button on remote control
for 2s. If you press button A, relay #1 will be triggered, if you
press button B, relay #2 will be triggered, and if you press button
C, both relays will trigger simultaneously.
EN
12

5. ADMINISTRATOR'S ROLE AND ADMINISTRATOR ENROLLMENT

Only an administrator can enrol and delete other users. The first
three stored fingerprints are entitled to administrator rights.
These can be the fingerprints of one, two or three individuals.
Carefully consider which finger you will choose for the
administrator finger. It should be without injuries and
have a prominent fingerprint. Do not enrol this finger
as a user finger later on, because this can result in prob-
lems with managing!
Administrator enrolment procedure:
Press button A for 3s. The white LED will start to flash quickly.
By pressing a button you choose which relay will be triggered
by the finger you are adding (button A, B or C). The green LED
flashes + a 1s beep is heard, the white LED starts to flash slowly.
Administrator then presses the finger he/she is enrolling on
the fingerprint reader for 7-10 seconds or until the green LED
flashes + a 1s beep is heard.
If enrolment is unsuccessful, the red LED flashes + three 1s
beeps are heard and the procedure has to be repeated.
When the administrator is correctly enrolled, the green LED
flashes + a 1s beep is heard. Repeat the same process with the
remaining two administrator fingerprints.
IMPORTANT:
Administrator fingers can be deleted only when the entire
database is deleted. Therefore you should carefully consid-
er who will be assigned with administrative rights, especial-
ly if the device will be used by several people.

6. USER FINGER ENROLMENT

After all administrators are enrolled, pressing button A for 3
seconds triggers the 'enrol user finger' function. The user's only
right is unlocking the door; a user cannot trigger any other
function.
User finger enrolment procedure
Press button A for 3s. The white LED starts to flash slowly.
The administrator presses his/her finger on the fingerprint
reader to confirm the beginning of enrolment of a user. After
positive identification of the administrator fingerprint, the
green LED flashes + a 1s beep is heard, the white LED starts to
flash quickly.
By pressing a button you choose which relay will be triggered
by the finger you are adding (button A, B or C). The green LED
flashes + a 1s beep is heard, the white and green LED start to
flash alternately.
The user now lays the finger he/she enrols on the fingerprint
reader for 7-10 seconds or until the green LED flashes + a 1s