1. Safety notes
Important notice to begin
Anyone who wishes to see these instructions on
video for more background information about
RESTUBE and the team may visit the following link: https://www.beuchat-diving.com/fr/produits/
611-beuchat-restube.html
Read the product information carefully before using the product!
Observe the notes inside the product and on the waist strap tag!
Check Beuchat Restube before each use, see chapter 2.
Should you detect defects during inspection,
please contact the dealer/manufacturer.
Never attempt to repair Beuchat Restube by yourself!
Beuchat Restube...
... only works as a floating device when it is completely inflated.
... only guarantees functionality when using the original BeuchatRestube-CO2-Cartridge (16g / 21ml).
... is not suitable for temperatures below 4°C.
... only wear Beuchat Restube on top of clothing, so that the trigger is accessible and the
floating device is not prevented from inflating!
... requires active use by the user and is therefore not suitable for people who are physi-
cally or mentally incapable of swimming.
... has a supporting function in water, but does not provide protection in case of uncon-
sciousness.
A slight trigger delay is possible in temperatures below 59°F (15°C). Carrying additional
weights or clothing reduces the perceived buoyancy of Beuchat Restube.
Make sure that supervision is nearby. Only put yourself in situations with Beuchat Restube
that you could handle safely without the product.
2. Operation and maintenance
2.1 How do I fasten Beuchat Restube correctly?
WARNING
Wearing the product loosely or open is dangerous! The product must be tightly
secured to prevent loss and enable functionality.
The provided waist strap may be inserted vertically or horizontally into the back
of the pocket.
>>> The options for attaching the strap have different advantages for wearing
the pocket on land or for practicing water sports. The user may choose the most
suitable position depending on the application and personal preferences.
19
>>>
NOTICE
Check the product's readiness for use (trigger and cartridge) before each use!
•
Open the pocket and verify that release lever is switched to the
green position
>>> If not, the CO2 cartridge may be empty. In this case,
>>> If the cartridge is pierced at its opening, it is empty
•
Verify that the buoy is in the correct position in the pocket
>>> The trigger mechanism must face the label with this
info@beuchat.fr
symbol
unscrew the CO2 cartridge
and must be replaced
sewn into the pocket