Regency Excalibur P90 Série Guide D'installation Et D'utilisation page 21

Foyer à évent direct à dégagement zéro
Masquer les pouces Voir aussi pour Excalibur P90 Série:
Table des Matières

Publicité

Description
Attic Insulation Shield 12"
Basic Horizontal Termination Kit (A )
Horizontal Termination Kit (B)
Vertical Termination Kit
High Wind Vertical Cap
High Wind Horizontal Cap
Horizontal Square Termination Cap
Vertical Termination Cap
Storm Collar
Adjustable Flashing 0/12-6/12
Adjustable Flashing 6/12-12/12
Vinyl Siding Standoff
Vinyl Siding Shield Plate
Snorkel Termination 14"
Snorkel Termination 36"
Restrictor Disk
Colinear Flex Connectors
FPI
946-604/P
Simpson Direct Vent or Astro Cap -Vent Guard (Optional)
770-994
Rigid Pipe Adaptor (Must use with all rigid piping)
**946-606
Starter collar reducer 5" x 8" to 4" x 6-5/8" (B36XTE, B36XTCE ONLY)
* Olympia Ventis DV applicable for the following units only: B36XTE, B36XTCE, B41XTE, B41XTCE, P36, P36E
**Note: When using Metal-Fab Sure Seal Rigid Piping - please note that the Adaptor (4DDA) must be used in conjunction with FPI Rigid Pipe Adaptor (510-994).
** Not available/applicable for the following units: B41XTE, B41XTCE, HZ54E
Offset Pipe Selection: Use this table to determine offset pipe lengths.
Pipe Length
(L)
Run (X)
0" (0mm)
5-11/16" (144mm)
6" (152mm)
8-13/16" (224mm)
9" (229mm)
10-15/16" (278mm)
12" (305mm)
13" (330mm)
24" (610mm)
21-7/16" (697mm)
36" (914mm)
29-13/16" (757mm)
48" (1219mm)
38-1/4" (972mm)
Simpson
Direct Vent Pro
®
58DVA-IS
N/A from FPI
N/A
58DVA-KHA
58DVA-VHA
58DVA-VCH
N/A
N/A
N/A
58DVA-SC
58DVA-F6
58DVA-F12
58DVA-VSS
N/A
58DVA-SNK14
58DVA-SNK36 (N/A - FPI)
58DVA-RD
N/A
5" x 8" Venting
Rise (Y)
15-5/16" (389mm)
18-7/16" (468mm)
20-9/16" (522mm)
22-11/16" (576mm)
31-1/16" (789mm)
39-7/16" (1002mm)
47-7/8" (1216mm)
Selkirk
Metal-Fab™
Direct Temp™
Sure Seal
N/A
N/A
5DT-HKA
N/A
5DT-HKB
N/A
5DT-VKC
N/A
N/A
N/A
N/A
N/A
5DT-HHC
5DHT
5DT-HVC
5DVT
5DT-SC
5DSC
5DT-AF6
5DF
5DT-AF12
5DF1-2
5DT-VS
5DVS
5DT-VSP
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
946-623/P
**946-506/P
946-625
For specifi c instructions on venting components - visit the
manufacturers website listed below.
Simpson Direct Vent Pro: www.duravent.com
Selkirk Direct-Temp: www.selkirkcorp.com
Metal-Fab Sure Seal: www.mtlfab.com
Industrial Chimney Company: www.icc-rsf.com
Note: Horizontal runs of vent must be level, or have a 1/4"
rise for every 1 foot of run towards the termination.
Never allow the vent to run downward - this could cause high
temperatures and may present a possible fi re hazard.
P90-10 Foyer à évent direct à dégagement zéro
installation
ICC Excel
Olympia
Ventis DV*
Direct
N/A
VDV-AIS05
TM-5HTK
VDV-KW05
TM-5HTK
VDV-K05
N/A
N/A
TM-5VT
VDV-VCH05
TM-5DHT
N/A
TM-5HT
VDV-HC05
N/A
N/A
TM-SC
VDV-SC05
TF-5FA
VDV-F0506
TF-5FB
VDV-F0512
TM-VSS
VDV-SSO
N/A
N/A
TM-5ST14
N/A
TM-5ST36
N/A
TM-5DS
N/A
N/A
N/A
AstroCap XL Horizontal Cap
Vent Guard (Optional)
Vinyl Siding Standoff - AstroCap XL
|
21
|
21

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

P90-ng10P90-lp10Excalibur p90

Table des Matières