Télécharger Imprimer la page

Kohler K-1652 Guide D'installation page 4

Générateur de vapeur
Masquer les pouces Voir aussi pour K-1652:

Publicité

Les langues disponibles

Les langues disponibles

Tee
Recommended In-Line
Water Filter
1. Determine the Layout
WARNING: Risk of property damage. Allow a minimum of 12" (30.5 cm) of air space around the
steam generator at all times. This provides an area for the heat generated by the unit to dissipate.
NOTICE: The steam generator will perform best when installed as close as possible to the steam head. The
unit should be installed within 25' (7.62 m) of the steam head.
NOTICE: For optimum performance install the steam generator below the level of the steam head.
NOTE: When possible, use 45 degree elbows. Performance will be increased when 45 degree elbows are
used.
NOTE: The "Recommended Layout Options" sections include information specific to Kohler bath and
shower products. Refer to those sections for additional layout information.
Determine the location of the steam generator. Allow for a 12" (30.5 cm) air gap on all sides of the
generator. Allow for a drain pan.
Choose a drain pan appropriate for your installation. The drain pan is not supplied.
1060226-2-G
Field Service Box
Install copper union
in water feed line.
Shut-Off
Valve
Control Cable
Input
Water Feed to Steam Generator
Pressure Relief Valve
Water
Inlet
Drain Pan
4
Install copper union as close
as possible to steam generator.
Steam Head
Kohler Co.

Publicité

loading

Ce manuel est également adapté pour:

K-1657K-1658K-1659K-1695K-1708K-1733 ... Afficher tout