Kohler K-1652 Guide D'installation page 10

Générateur de vapeur
Masquer les pouces Voir aussi pour K-1652:

Publicité

Les langues disponibles

Les langues disponibles

Tee
Shut-Off
Valve
Water
Inlet
Recommended
In-Line Water Filter
Control Cable
Input
Steam Trap
Do not run steam line down and then up.
This will create a steam trap.
6. Install the Water Supply Line and Steam Line
WARNING: Risk of personal injury or property damage. Do not plumb the pressure relief valve
into the steam line. Plumbing the pressure relief valve into the steam line can create a hazard if the
steam line is blocked or obstructed.
WARNING: Risk of scalding. Do not plumb a trap, shut-off valve, or pressure relief valve into the
steam line. Plumbing the pressure relief valve into the steam line can be hazardous, if the steam
outlet is capped.
WARNING: Risk of personal injury or property damage. Do not direct the pressure relief valve to
the enclosure. In the event the pressure relief valve activates, the hot water may spray causing
burns to the user and/or damage the enclosure. Therefore, the pressure relief valve should be
directed to an area where damage will not occur from contact with hot water and should conform
to national and local plumbing codes.
Install the Water Supply Line to the Generator
NOTE: For all NPT threaded connections, use pipe tape or pipe sealant. Do not overtighten the fittings.
Connect to an existing cold water line, and run a 3/8" cold water line to a shut-off valve before the
in-line water filter.
Before final connection to the steam generator, flush out the water supply line into a large pail. This
removes any debris, silt, sand, or other material that may be in the line.
Install 3/8" copper tubing with a union fitting between the in-line water filter and the water inlet to
the steam generator.
Connect the water supply line to the steam generator.
Make sure that the water drain valve on the generator is closed.
1060226-2-G
Pressure Relief Valve
Copper
Union
Copper
Pitch toward generator.
Union
Provide clearance
from wall.
6" (15.2 cm)
from Floor
10
Steam
Head
1" (2.5 cm) Min
2-1/2" (6.4 cm)
Temporary
Nipple
Wall Stud
Kohler Co.