INSTALLATION

General

Hatco Multi Contact Grills are shipped pre-assembled and
ready to use. Care should be taken when unpacking the
shipping carton to avoid damage to the unit. The following
installation procedure must be performed before connecting
electricity and operating the unit.
WARNING
ELECTRIC SHOCK HAZARD: Unit is not weatherproof.
Locate unit indoors where ambient air temperature is a
minimum of 50°F (10°C) and a maximum of 95°F (35°C).

FIRE HAZARD:

• Locate unit a minimum of 8" (203 mm) from combustible
walls and materials. If safe distances are not maintained,
discoloration or combustion could occur.
• Do not obstruct air ventilation openings on outer
housing of unit. Unit combustion or malfunction may
occur.
1. Inspect the shipping carton for obvious signs of transit
damage. If damaged, inform the freight company
immediately. CAUTION! Stop! Do not attempt to use
unit if damaged. Contact Hatco for assistance.
2. Remove the unit and any loose components/accessories
from the shipping carton. The following loose components
are included in every Multi Contact Grill:
• Grease Trap
• Hex Wrench (for top grill plate balancing)
NOTE: To prevent delay in obtaining warranty coverage,
complete online warranty registration. See the
IMPORTANT OWNER INFORMATION section for
details.
3. Remove tape and protective packaging from all surfaces
of the unit.
• Make sure to remove all protective film from the stainless
steel surfaces.
4. Inspect the unit for freight damage such as dents in
housing or broken knobs. If damaged, inform the freight
company immediately.
Locate unit at proper counter height in an area that is
convenient for use. Location should be level and strong
enough to support weight of unit and contents.
Do not locate unit in an area subject to excessive
temperatures or grease from grills, fryers, etc. Excessive
temperatures and grease could cause damage to unit.
Unit is recommended for use in or on metallic countertops.
For other surfaces, verify with manufacturer that material
is suitable for prolonged temperatures up to 200°F (93°C).
Damage to any countertop material caused by heat
generated from Hatco equipment is not covered under
Hatco warranty.
5. Place the unit in the desired location.
• Locate the unit in an area where the ambient air
temperature is constant and a minimum of 50°F (10°C)
to a maximum of 95°F (35°C). Avoid areas that may be
subject to active air movements or currents (i.e., near
exhaust fans/hoods and air conditioning ducts).
• Make sure the unit is at the proper counter height in an
area convenient for use.
• Make sure the countertop is level and strong enough to
support the weight of the unit and food product.
• Make sure all the feet on the bottom of the unit are
positioned securely on the countertop.
6. Attach the swing arm to the top
grill plate assembly.
• Lift up the swing arm and
place the cutout on the swing
arm over the retaining screw
on the top grill plate.
6
English
CAUTION
NOTICE
Retaining
Screw
Swing
Arm
Form No. MCGM-0418