Télécharger Imprimer la page

Festo CPV GE-ASI-8E8A Serie Notice Simplifiee page 23

Masquer les pouces Voir aussi pour CPV GE-ASI-8E8A Serie:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 39
CPV..-GE-ASI-8E8E-...
Example:
– 3 double-solenoid valves, 2 single-solenoid valves
– 2 consecutive AS-Interface addresses:
slave n: E0...3, A0...3; slave n+x: E4...7, A4...7
Addresses of the inputs
Addresses of the outputs
J = 2 double-solenoid valves, M = single-solenoid valves, L = blank plate
1
2
Slave 1: I/Os of the AS-Interface address n (valve slots 1 to 4)
3
Slave 2: I/Os of the AS-Interface address n+1 (valve slots 5 to 8)
Symbol for valve plates (example: J, M, L)
3.7 Conversion of the CP valve terminal
The CP valve terminal can be fitted with double-solenoid valves
and/or with single-solenoid valves. If the valve terminal is con-
verted, the new configuration must be set by means of a DIP
switch on the bottom of the sub-base. Instructions on removing
the sub-base can be found in the pneumatics manual.
9907NH
E 36.4...7
E 36.0...3
1
0
1
2
3
4
5
0
1
2
3
4
5
3
J
L
J
L
J
L M M
12
1
3
5
14
0
2
4
E 36.0...3
E 36.4...7
2
6
7
6
7
6
7
23

Publicité

loading