Les langues disponibles

Description
S0002P - External, two-channel, 12-24 V AC - DC IP54 control card for keypads and transponder.
Description of parts
❶ Save code key for channel 1 (OUT1)
❷ Save code key for channel 2 (OUT2)
❸ Delete all code key
❹ Warning LED
❺ Expansion board
❻ Terminals for channel outputs OUT1 and OUT2
❼ Power supply terminals
❽ Terminals for connecting accessories
Size
Installation
Fix the board container in a place protected from knocks.
The distance between the S0002P card and the keypad selector or transponder must be
max. 30 m.
Connections
Connect up the electrics as shown in the figure.
Connect up to 4 keypad selectors or 4 transponder selectors.
Use H05RN-F cables that are 60245 IEC 57 (IEC) compliant.
Incoming current protection / limitation of 500 mA is recommended.
Technical data
Type
Power supply (V AC/DC)
Protection rating (IP)
Maximum power draw at 24V AC (mA)
Number of relay contacts
24V DC max relay capacity (A)
Max. users
Operating temperature (°C)
Device class
* OUT1 = Monostable, OUT2 = configurable as Monostable (default) / Bistable / Hold-to-run.
** With the expansion board inserted.
806SL-0370
12 - 24
54
350
2*
1
250**
-20 to +55
III