Make sure nothing is under the lifting structure or the vehicle and all unautherized personnel
IMPORTANT
are away from the lift area.
1.
Review instructions before using the MANUAL
LOWERING KIT (MLK)
2.
Remove fill plug from MLK, Fig 6.
3.
Fill with Dexron III ATF or ISOVG32 Hydraulic
Oil, replace plug once unit is full.
4.
Remove cap from end of hose on MLK, Fig 6.
5.
Rotate the MLK Valve clockwise to open, Fig 6.
6.
SLOWLY hand pump MLK until
IMPORTANT
fluid begins to flow from the end of the hose.
7.
Hand tighten the female half coupling to the
end of the MLK using pipe thread sealant, Fig 6.
MLK Valve
Fill Plug
8.
Using wrench tighten half coupling 1.5-3.0 turns
past finger tight.
9.
Open power unit cover and push red handle lo-
cated on solenoid, Fig 2, this will release any
pressure in the lift system.
10.
Remove and save plug from power unit port
marked "M", Fig 1, attach and hand tighten half
coupling already mated to #4 "O"-ring adapter
fitting provided to port marked "M".
11.
Using wrench tighten half coupling ½ turn after
"O"-ring makes contact with power unit valve
body.
12.
Attach ½ coupling mounted on MLK to new 90°
elbow just installed to power unit valve body.
13.
Pump handle on MLK approximately 100-200
times to raise lift until the latch can be
released.
Manual Lowering Kit Operating Instructions
Half-Coupling
MLK
Fig. 1
12