Micropulse Transducer - Rod Style
8
Technical data
8.1
Accuracy
The specifications are typical values for BTL7-S... at
24 V DC, at room temperature, and with a nominal length
of 500 mm in conjunction with the BTL-P-1013-4R,
BTL-P-1013-4S, BTL-P-1012-4R or BTL-P-1014-2R
magnet.
The transducer is fully operational immediately, with full
accuracy after warm-up.
For special versions, other technical data may
apply.
Special versions are indicated by the suffix -SA
on the part label.
Position resolution
Non-linearity at
Nominal length 25 to 5500 mm
resolution ≤ 10 µm
resolution > 10 µm
Nominal length 5501 to
7620 mm
Hysteresis
Repeat accuracy
Temperature coefficient
1)
Speed resolution
Min. detectable speed
Max. detectable speed
8.2
Ambient conditions
Operating temperature
Operating temperature for UL
(only BTL7...-KA...)
Storage temperature
Relative humidity
Rod pressure rating
(when installed in hydraulic
cylinders)
For Ø 8 mm
For Ø 10.2 mm
Shock rating
Continuous shock
per EN 60068-2-27
3)
18
english
1, 2, 5, 10, 20, 40, 50,
100 µm
(additionally 200, 500,
1000 µm with
BTL7-S510(B)-...)
≤ ±30 µm
≤ ±2 LSB
±0,02 %
≤ ±7 µm
≤ ±5 µm (typ. ±2.5 µm)
≤ 15 ppm/K
0.1 mm/s
1 mm/s
10 m/s
2)
−40°C to +85°C
Max. +80°C
−40°C to +100°C
< 90%, non-condensing
< 250 bar
< 600 bar
150 g/6 ms
150 g/2 ms
Vibration
per EN 60068-2-6
3)
(note resonant frequency
of the rod)
Degree of protection per
IEC 60529
Connector S32/S147
(when attached)
Cable
8.3
Supply voltage
Voltage, stabilized
4)
Ripple
Current draw (at 24 V DC)
Inrush current
Reverse polarity protection
Overvoltage protection
Dielectric strength
(GND to housing)
8.4
Communication lines La, Lb
Short-circuit protection
Nominal length 500 mm, magnet in the middle of the measuring range
1)
For
: Use in enclosed spaces and up to a height of 2000 m above sea
2)
level.
Individual specifications as per Balluff factory standard
3)
For
: The transducer must be externally connected via a limited-
4)
energy circuit as defined in UL 61010-1, a low-power source as defined in
UL 60950-1, or a class 2 power supply as defined in UL 1310 or
UL 1585.
20 g, 10 to 2000 Hz
IP 67
IP 68
3)
10 to 30 V DC
≤ 0.5 V
ss
≤ 120 mA
≤ 500 mA
Up to 36 V
(supply to GND)
Up to 36 V
500 V DC
Signal cable to GND