Position switches
enclosed
Operating Instructions
Read and understand these instructions before installing, operating, or maintaining
the equipment.
!
DANGER
Hazardous voltage.
Will cause death or serious injury.
Disconnect power before working on
equipment.
Reliable functioning of the equipment is only ensured with certified components.
Installation
For dimension drawings, see Figure I (Dimensions in mm)
To be mounted on level surfaces using: 2 M5 screws for 3SE.1.0/230
Always add washers and spring washers.
Any mounting position possible.
1
) Lever in end position
Operation
see Figure II
A) Drive: actuated by straight bar in lifting direction and laterally
6
7
(applies to narrow
) and wide
a) Single plunger
b) Rounded plunger
c) Roller plunger
d) Roller lever
e) Angled roller lever
f) Roller crank
g) Length-adjustable roller crank
h) Rod actuator
(aluminum rod)
(molded-plastic rod) 3SE....-.WW..., 3SE.230-.W...
i) Spring rod
(snap-action contact only, can be actuated from any direction)
j) Fork lever
1
) Operating range
2
) Lower edge of actuator
3
) Mechanical contact section of rod
4
) Minimum deflection (to ensure reliable operation)
5
) Maximum deflection (to prevent damage)
Operating point to DIN EN 50041
V
max. actuating speed
max.
H
Actuator travel difference
Direction of actuation
Minimum force requirement in direction of actuation:
for 3SE.1.0/303/404/230-.B, E, F, R
for 3SE.1.0/303/404/230-.C, D
Minimum torque in direction of actuation:
for 3SE.1.0/303/404/230-.GW, UW, WW
B) Contact elements
a) Creep-action contacts
b) Creep-action contacts (make-before-break)
c) Snap-action contacts
Connection designation to EN 50013
The switching point of snap-action contacts remains constant throughout the
entire tool life, independent of contact erosion.
C) Nominal actuator travel and relevant terminals
a)
in direction of travel
b)
with lateral actuation
c)
Deflection in direction of rotation
d)
Deflection of the spring rod
0-line
Reference line to DIN EN 50041
s)
Actuator travel to DIN EN 50041
H)
Actuator travel distance
Contact closed
Contact open
1
)
Operating point for return travel
2
)
Enforced opening to DIN IEC 60947-5-1
Conductor cross-sections and connecting torque:
Carefully seal the M20 x 1.5/Pg 13.5 cable entry to retain the degree of protection
standard.
Changeover mechanism for 3SE.120-/230: refer to Fig. IV
Parts are packed as loose parts. Mount intermediate plate (b) on the position switch
(a). Install base plate (c) at the mounting location. Put the position switch into place
and lock it by means of the interlocking lever (d).
2
4 M5 screws for 3SE.303/404.
) enclosures)
3SE....-.B...
3SE....-.C...
3SE....-.D...
3SE....-.E...
3SE....-.F...
3SE....-.GW...
3SE....-.UW..., 3SE.230-.U...
3SE....-.VW..., 3SE.230-.V...
3SE....-.R...
3SE....-.T...
refer to Fig. III
EN 60947-5-1/IEC 60947-5-1 (VDE 0600 Part 200)
Order No.: 3ZX1012-0SE32-0BA1
Modification options
All of the drives can be replaced by other drive concepts.
All of the drives can be offset by 4 x 90 °, so that (depending on the form of enclosure)
actuation can be carried out from four sides.
For 3SE.1.0/303/404-.GW, UW, WW, VW
For 3SE.230-.GW, U, W, V
These drives can be offset on the drive shaft by 10 ° to 10 ° and turned around by
180 ° (screw must be loosened).
Securing against position change (fixing)
If used as a safety position switch, positive fixing is required. If fixed by means of
oblong holes, locating pins or fixing pads must additionally be used.
Protection against actuation and overriding
Position switches should be arranged so that they will not be damaged during actua-
tion and overriding. They must therefore not be used as a mechanical stop. The height
of the skate or the cam should be less than the entire travel in the switch to avoid me-
chanical loading of the switch or its fixing arrangement.
Maintenance
Replacing the switching insert
Remove the screws of the enclosure cover, lift the switching insert from the upper
edge with a screwdriver. Push the new insert onto the two spigots in the enclosure
until it reaches its stop position.
Order numbers for switching inserts: refer to Fig. V
a)
Order number switching insert
b)
Element type refer to 'Operation' section, part B) a), b), c)
c)
for position switch
Technical data
Degree of protection to DIN VDE 0470 and IEC 60529
-
metal-enclosed
-
molded-plastic enclosed
Permissible ambient temperature during operation –30 to +85 °C
Degree of pollution to DIN VDE 0110
Mechanical life
for 3SE21.0-8..., 3SE2230-8...
Electrical life
(with contactors 3RH11, 3RT10, 3RT10 17,
3RT10 24 to 3RT10 26)
Utilization category I
Switching frequency
(mit Schütz 3RH11, 3RT10, 3RT10 17,
3RT10 24 bis 3RT10 26)
for 3SE21.0-8..., 3SE2230-8...
Switching accuracy
(when switching repeatedly, measured
at the plunger of the contact element)
Rated insulation voltage U
9 N
Rated operational voltage U
18 N
only identical potential at U
Thermal rated current I
0.25 Nm
Rated operational voltage I
AC current 40 to 60 Hz
at U
24 V/125 V
e
230/220 V
400/380 V
500 V
DC current
at U
24 V
e
48 V
110 V, 125 V
220 V, 250 V
440 V, 600 V
1
) 6 A for 3SE21.0-8..., 3SE2230-8...
2
) for 3SE21.0-8..., 3SE2230-8...
Short-circuit protection with DIAZED fuse links
weld-free acc. to VDE 0660 Part 200
Utilization category:
UL data
Rated voltage
for 3SE21.0-8..., 3SE2230-8...
Switching capacity
for 3SE21.0-8..., 3SE2230-8...
Continuous current
3SE.100, 3SE.120, 3SE.230
3SE.303, 3SE.404
IP67
IP66
Class 3
30 x 10
15 x 10
10 x 10
/AC-15 at 230 V
0.5 x 10
e
6000 switching cycles/hour
1800 switching cycles/hour
0.05 mm
500 V
i
AC 500 V
e
>300 V AC
e
10 A
th
e
I
/AC-12
e
10 A
10 A
10 A
10 A
I
/DC-12
e
10 A
2
)
2
)
2
)
0.5 A
gL/gG
6 A
quick
10 A (not for 3SE21.0-8..., 3SE2230-8...)
600 V
300 V
Heavy Duty, A600 / Q600
Heavy Duty, A300 / Q600
10 A
English
6
switching cycles
6
switching cycles
6
switching cycles
6
switching cycles
I
/AC-15
e
1
1
)
10 A
)
1
)
6 A
1
)
4 A
1
)
3 A
I
/DC-13
e
1
1
)
10 A
)
6 A
4 A
4 A
1 A
2
1 A
0.4 A, 0.27 A
)
2
0.2 A, 0.1 A
)

Publicité

loading

Ce manuel est également adapté pour:

3se.1203se.2303se.3033se.404