Natural Gas Installation
Only licensed gas fitters must perform the required gas fitting on NewAge gas appliances.
To ensure satisfactory performance, the gas supply line must be sized to accommodate the total
BTU/h requirements of all the gas-fired equipment that will be connected to that line.
In no case should pipe less than 3/4" inside diameter or 1" outside diameter ever be used to
connect this product.
Calculate the total BTU output of all equipment and refer to Gas Supply Line Runs for allowable
run distances for ¾ inch pipe. Failure to meet these minimum requirements may reduce
performance of the side burner and any other appliances running on that supply line.
Always keep supply line runs as short as possible.
A gas shut-off valve must be installed in an easily accessible location by a licensed gas fitter.
The outdoor cooking gas appliance and its individual shut-off valve must be disconnected from
the gas supply piping system during any pressure testing of that system at test pressures in
excess of 0.5 psi (3.5 kPa).
The outdoor cooking gas appliance must be isolated from the gas supply piping system by
closing its individual manual shut-off valve during any pressure testing of the gas supply piping
system at test pressures equal to or less than 1/2 psi (3.5 kPa).
Keep threading compound off of the first two pipe threads to avoid having any small pieces of
compound break loose and clog a burner valve or orifice. Do not use threading compound on
any flare fittings.
For built-in installations, it is recommended that any flexible pipe used be kept as short as possible.
For freestanding units using natural gas, NewAge strongly recommends using a quick disconnect
kit. This Quick Disconnect kit, is included with purchase.
Note:
This product must be installed by a licensed plumber or gas fitter when installed within the State of
Massachusetts.
This illustration is for reference only
each installation will be different.
Side burner Intake
Gas Hose (Not
Manifold
20
Flexible
Threaded
Corrugated
Supplied)
WARNING
Main shut-off valve
Threaded
nipple
Flexible
Gas Hose
Quick
nipple
Disconnect
Coupler
Quick
Disconnect
Gas supply line