Instructions For Maintenance; Reminders For The Maintenance Technician; Conversion To Another Type Of Gas; Commissioning - Gastro M 70/40 GRACQE Serie Installation-Emploi-Entretien

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 27
INSTRUCTIONS FOR
V.
MAINTENANCE
16.
REMINDERS FOR THE MAINTENANCE
TECHNICIAN
THE MANUFACTURER WILL NOT BE
LIABLE FOR ANY DAMAGE OR INJURY
RESULTING FROM FAILURE TO
OBSERVING THE FOLLOWING RULES.
Identify the specific appliance model. The model
number is detailed on the packing and on the
appliance dataplate.
The appliance must be installed in a well-ventilated
room.
Do not obstruct any air vents or drains present on
the appliance.
Do not tamper with appliance components.
Appliance maintenance and conversion to a
different type of gas must be carried out by
qualified
technicians
manufacturer, in compliance with current safety
standards and the instructions in this manual.
17.
CONVERSION TO ANOTHER TYPE OF
GAS
See Chapter " Instructions for installation ".
18.

COMMISSIONING

See Chapter " Instructions for installation ".
19.

TROUBLESHOOTING

GAS GRILL
The pilot burner does not light.
Possible causes:
- Insufficient gas supply pressure.
- Blocked tubing or nozzle.
- Defective gas tap or valve.
- Igniter defective or not properly connected.
- Igniter or igniter wire defective.
authorized
by
the
Pilot burner goes out during use.
Possible causes:
- Insufficient gas supply pressure.
- Defective gas tap or valve.
- Defective thermocouple or insufficient heating.
- Thermocouple incorrectly connected to gas tap or
valve.
-
Knob of gas tap or valve not pressedsufficiently.
The main burner does not light (even though pilot is
lit).
Possible causes:
- Defective burner (gas outlet holes clogged).
ELECTRIC GRILL
The appliance does not heat.
Possible causes:
- Temperature thermostat defective.
- Heating elements defective.
Heating cannot be adjusted.
Possible causes:
- Temperature thermostat defective.
GAS LAVA STONE GRILL
The pilot burner does not light.
Possible causes:
- Insufficient gas supply pressure.
- Blocked tubing or nozzle.
- Defective gas tap or valve.
- Igniter defective or not properly connected.
- Igniter or igniter wire defective.
Pilot burner goes out during use.
Possible causes:
- Insufficient gas supply pressure.
- Defective gas tap or valve.
- Defective thermocouple or insufficient heating.
- Thermocouple incorrectly connected to gas tap or
valve.
-
Knob of gas tap or valve not pressedsufficiently.
The main burner does not light (even though pilot is
lit).
Possible causes:
24

Publicité

Table des Matières
loading

Table des Matières