Télécharger Imprimer la page

ELLETRO TURBO 215 Manuel D'instructions page 9

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 13
power plug from socket before maintenance and servicing.
MOVING PARTS can cause serious injury.
- Keep away from moving parts.
HOT SURFACES can cause severe burns.
- Allow the cooling of the unit before servicing.
3.2 WELDING MACHINE MAINTENANCE
Experience has shown that many fatal accidents originated from
servicing which had not been perfectly executed. For this
reason, a careful and thorough inspection on a serviced welding
machine is just as important as one carried out on a new
welding machine.
Furthermore, in this way manufacturer can be protected from
being held responsible for defects when the fault is someone
else.
3.2.1 Prescriptions to follow for servicing
After rewinding the transformer or the inductances, the welding
machine must pass the voltage test applied according to that
indicated in table 2 of the EN 50060/A1 standard.
- If no rewinding is done, a welding machine which has been
cleaned and/or reconditioned must pass a voltage test applied
with voltage values equal to 50% of the values given in table 2
of EN 50060/A1 standard.
- After rewinding and/or the replacement of parts, the No-Load
voltage should not exceed the values given in 10.1 of EN
50060/A1standard.
- If the servicing is not done by the manufacturer, the repaired
welding
machines
which
modifications of any component, should be labelled in a way
such that the identity of the person having serviced is clear.
3.3 TROUBLE SHOOTING
DEFECT
PROBABLE CAUSE REMEDY
The welding
Switch in OFF
machine does not
position.
supply current;
completely
inoperative
Plug not correctly
connected.
The welding machi-
The input supply
ne supplies a
voltage is different
feeble current.
from the voltage
required by the
machine.
The thermostat light
The thermostat is
is alight.
open.
underwent
replacements
Switch to ON
position.
Connect it
properly.
Check it.
Await some
minutes to have
the reset of the
thermostat
or
9

Publicité