MAINTENANCE

TO REPLACE THE STYLUS
- Put the rest clip on the pick-up arm.
- Remove the protective cap from the stylus.
- Pull the stylus to the lower front and remove it.
- Put in the new stylus following the reverse procedure.
- Replace the protective cap on the stylus.
TO REMOVE THE CARTRIDGE
- Put the rest clip on the pick-up arm.
- Remove the stylus to prevent damage.
- Remove the two cartridge fi xing screws.
- Disconnect the four link wires at the back of the cartridge.
TO INSTALL NEW CARTRIDGE
- Connect the four link wires.
- Take care of the receptacle's colors.
- Install the cartridge in the head shell.
- Install the two cartridge fi xing screws.
- Re-install the stylus.
- Replace the protective cap on the stylus.
IMPORTANT RECOMMENDATIONS
We advise you to clean your records using a rag impregnate with an antistatic
product for maximum enjoyment of your records and also to make them last.
We would also point out that for the same reason your stylus should be replaced
periodically (approximately every 250 hours).
Dust the stylus from time to time using a very soft brush dipped in alcohol
(brushing from back to front of the cartridge).
WHEN TRANSPORTING YOUR RECORD PLAYER DO NOT FORGET TO:
Replace the protective cap on the stylus.
Disconnect the drive belt by stretching it over the motor pully, and allow it to wrap
back around the inner drive area and then remove the platter by pulling it straight
up off the spindle.
Put the rest clip into the pick-up arm.