F. Slower movement and closer approach of the probe normally
improve the likelihood of finding a leak. However, detectors made to
meet this standard are based on air sampling from the 9.5 mm
(3/8 in) distance. Retest is advisable when a leak appears to be
found at the most sensitive settings, particularly if the probe was in
a static position on a joint, or making physical contact with a joint, as
it was moving. Repeat with a moving probe test at that location,
taking care to maintain the small gap (9.5 mm or 3/8 in) to confirm
that the leak is of repairable size.
G. The TIF IR-1A is sensitive and can take up to 30 seconds to clear
after detecting a small amount of contaminant. It will typically clear
in 2 to 15 seconds.
CAuTION: Do not use cleaning agents or solvents on or near A/C
lines. Wipe away any dirt or potential false-trigger chemicals
using a dry towel or fresh air.