Télécharger Imprimer la page

Abus FU8380 Mode D'emploi page 17

Détecteur de choc radio
Masquer les pouces Voir aussi pour FU8380:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 23
Position
In order to guarantee problem-free
operation, the detector must NOT be
mounted in the following locations:
- Next to the floor
- Near large metal structures
- Less than 1 metre away from power or
gas lines
- Near electronic or wireless devices
- On moveable elements
- Upside down
When large areas are monitored, the
distance between two detectors cannot be
more than 10 metres.
Installation
1. Open the housing by loosening the
screw on the front of the sensor and
removing the cover.
2. Remove the PCB from the housing by
pulling it carefully from the plastic
clamps.
3. Hold the housing base at the desired
position on the wall and mark the screw
positions for fixing.
4. Fix the rear housing side in the marked
position with two screws. The rear of the
17

Publicité

loading

Ce manuel est également adapté pour:

095947