5 SCPI Programming Reference
Parameter
0.00001024 – 0.30, *RST 0.001
Programs a constant dwell time of 0.2 seconds: ARB:CURR:CDW:DWEL 0.2
You can program dwell times that are much faster than the response time of the instrument. The
l
"extra" points and dwell times can serve the purpose of smoothing the resultant waveshape.
[SOURce:]ARB:CURRent:CDWell:POINts?
[SOURce:]ARB:VOLTage:CDWell:POINts?
Returns the number of points in the Arb.
Parameter
(none)
Returns the number of current points in the Arb: ARB:CURR:CDW:POIN?
[SOURce:]ARB:FUNCtion:TYPE CURRent|VOLTage
[SOURce:]ARB:FUNCtion:TYPE?
Specifies either a voltage or current Arb. Only one type of Arb may be output at a time. The selection
must match the priority mode.
Parameter
CURRent|VOLTage, *RST VOLTage
Specifies a voltage Arb: ARB:FUNC:TYPE VOLT
[SOURce:]ARB:TERMinate:LAST 0|OFF|1|ON
[SOURce:]ARB:TERMinate:LAST?
Selects the output setting after the Arb ends. When ON (1), the output voltage or current remains at
the last Arb value. The last Arb voltage or current value becomes the IMMediate value when the ARB
completes. When OFF (0), and also when the Arb is aborted, the output returns to the settings that
were in effect before the Arb started.
Parameter
0|OFF|1|ON, *RST OFF
Terminate with the output at the last Arb value: ARB:TERM:LAST ON
190
Typical Return
<dwell value>
Typical Return
<points>
Typical Return
VOLT or CURR
Typical Return
0 or 1
Keysight RP7900 Series Operating and Service Guide