Figure 3
2. Use wrenches provided to loosen jam
nut on jaw housing (See Figure 3).
3. Turn jaw counter-clockwise making
jaws tighten on rivet. Turn clockwise
to loosen jaws on rivet (See Figure 2).
NOTE: Only turn jaw housing in 1/4 turn
increments.
4. Tighten jam nut.
5. Reassemble chrome nose cap.
6. Check function of rivet in tool.
Re-adjust again if necessary.
Maintenance
Release all pressure before
attempting to install, service,
relocate or perform any maintenance on
the air system. personal injury and/or
property damage could occur.
hydRaulIc cylIndeR
Occasionally, the hydraulic cylinder will
need hydraulic fluid. To fill the hydraulic
cylinder, follow the procedure outlined
below (See Figure 4).
www.campbellhausfeld.com
Bottom
Plate
Piston
Bore
Hydraulic
Fluid Fill Level
Safety Cap
and Frame Cap Nut
Figure 4
1. Release all system pressure and
disconnect the rivet gun.
2. Hold gun upside down.
3. Remove bottom plate and air piston.
4. Look into small bore at bottom of
chamber to check hydraulic oil level.
5. Hydraulic oil level should be about
1/2" from top of small piston bore
(total capacity: 60 - 70 cc).
stoRaGe
The rivet gun must be lubricated
before storing. Follow the lubrication
instructions with the exception of step
4. Trigger the gun only once or twice
because more oil needs to remain in the
gun for storage.