technical area

Warning
To guarantee safety and correct opera-
tion of the system interface, it must be
commissioned by a qualifi ed technician
in possession of the skills as required
by law.
Ignition procedure
- Insert the system interface into the
connection shoe by pushing it gently
downwards; after a brief initialisation,
the system interface will be connected.
- The display screen shows "Select lan-
guage. Turn the knob and select the
desired language. Press the OK button
to confi rm.
- The display shows the date and time.
Use the knob to select the date, press
the OK button, turn the knob to select
the exact day, press the OK button to
confi rm and move on to the month, fol-
lowed by the year, pressing the OK but-
ton to confi rm after each step.
Turn the knob to select the time, press
the OK button, turn the knob to select
the exact hour, press the OK button
to confi rm and move on to the minute
value.
Press the OK button to confi rm.
Turn the knob and select summer
time, press the OK button, select auto
or manual, press the OK button.
The display shows the basic screen.
- Simultaneously press the back "
and "OK" buttons until "Enter code"
appears on the display.
- Turn the knob to enter the technical
code (234) then press OK; the display
will show TECHNICAL AREA:
- Language, date and time
- BridgeNet Bus network settings
- Complete Menu
- Confi guration Wizard
- Service
- Faults
Turn the knob and select:
- BridgeNet Bus network settings
The display will show the list of devices
connected within the system:
- System interface (local)
- Solar control
- Boiler
- Energy Manager
- ...
The confi gurable devices are marked by
the "
" symbol.
To set the correct zone to which the sy-
stem interface is associated, turn the
knob and select:
- System Interface (Local)
Press the OK button.
Turn the knob and set the correct zone.
Press OK to confi rm the setting.
Turn the knob and select:
- COMPLETE MENU
Press the OK button.
Turn the knob and scroll through the
menus available for selection:
0
Network
1
Time-Date-Language
2
Boiler Parameters
3
Solar
4
Zone 1 Parameters
5
Zone 2 Parameters
6
Zone 3 Parameters
"
7
Zone Module
8
Service Parameters
9
Hybrid Parameters
10
Fresh Water Station