Atag VA8117TT Notice D'utilisation page 79

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

NOTE!
Do not forget to refit the drainage pump stop.
Unblocking the inlet hose filter
If the water supply contains small particles, the outer filter on the inlet hose may become blocked,
which results in Water inlet fault.
1. Turn off the machine using the main power switch and unplug it from the wall socket.
2. Turn off the water tap.
3. Unscrew the inlet hose.
4. Carefully remove the outer filter from the inlet hose and clean it.
5. Refit the filter and check that the gasket is correctly positioned.
6. Screw the inlet hose firmly into place.
7. Plug the machine into the wall socket and turn on the water tap. Allow the pressure to settle for
a while and check that the connection is watertight.
Drainage pump
stop
Outer filter on
inlet hose
Gasket
Care and cleaning
31

Publicité

Table des Matières
loading

Table des Matières