3.
With a socket spanner 7 remove the
injectors and replace them with the
ones which are necessary for the type
of gas you use (see table in "Techni-
cal Information" chapter).
4.
Assemble the parts, follow the same
procedure backwards.
5.
Replace the rating plate (it is near the
gas supply pipe) with the one for the
new type of gas supply. You can find
this plate in the package supplied
with the appliance.
If the supply gas pressure is changeable
or different from the necessary pressure,
you must fit an applicable pressure ad-
juster on the gas supply pipe.
8.4 Adjustment of minimum level
To adjust the minimum level of the burn-
ers:
1.
Light the burner.
2.
Turn the knob on the minimum posi-
tion.
3.
Remove the knob.
4.
With a thin screwdriver, adjust the by-
pass screw position.
A
A)
The by-pass screw
• If you change from natural gas G20 20
mbar to liquid gas, fully tighten the by-
pass screw in.
• If you change from liquid gas to natural
gas G20 20 mbar, undo the by-pass
screw approximately 1/4 of a turn (1/2
of a turn for Triple Crown burner).
WARNING!
Make sure the flame does not go
out when you quickly turn the
knob from the maximum position
to the minimum position.
8.5 Electrical connection
• Do not pull the mains cable to discon-
nect the appliance. Always pull the
mains plug.
• The appliance must not be connected
with an extension cable, an adapter or
a multiple socket. There is a risk of fire.
• Do not let the power cable to heat up
to a temperature of more than 90° C.
The cable should be guided by means
of clamps fixed to the side of the cabi-
net, in order to avoid any contact with
the equipment beneath the cooktop.
• Make sure that there is access to the
mains plug after the installation.
Electrical Requirements
Permanent electrical installation must
agree with the latest I.E.E. Regulations
and local Electricity Board regulations. For
your own safety the installation must be
done by a qualified electrician (e.g. your
local Electricity Board, or a contractor
who is on the roll of the National Inspec-
tion Council for Electrical Installation Con-
tracting [NICEIC]).
The manufacturer refuses to
be held responsible, if these
safety measures are not abi-
ded by.
Supply connections:
This hob has to be connected to 230 —
240 V ( 50 Hz) electricity supply.
The hob has a terminal block which is
marked as follows:
• L — Live terminal
• N — Neutral terminal
or E — Earth terminal
Before carrying out the connection, make
sure:
1.
The limiter valve and the electrical
system can take the appliance load
(see the rating plate)
2.
The supply system is equipped with
an efficient earth connection in com-
pliance with the current standards
and regulations
3.
The outlet or omnipolar switch used
for connection is easily accessible
with the appliance installed.