Kohler K-3900 Mode D'emploi page 5

Masquer les pouces Voir aussi pour K-3900:

Publicité

Les langues disponibles

Les langues disponibles

29-1/2" (749 mm)
3-3/4" (95 mm),
3-9/16" (90 mm) Min
Optional
Supply,
1/2" OD
Compression
Outlet Thread
38" (965 mm) - 66" (1676 mm)
1-3/4"
(44 mm),
1-1/2"
(38 mm)
Min
36-1/4"
(921 mm)
12" (305 mm)
Roughing-in - Wall Mount Electrical and Water Supply
WARNING: Risk of electric shock. Disconnect power before servicing.
WARNING: Risk of electrical shock. For plug-in installations/wall-mounted electrical supply:
Connect only to a properly-grounded, grounding-type receptacle which is protected by a
Ground-Fault Circuit-Interrupter (GFCI) or Residual Current Device (RCD). Do not remove the
grounding pin or use a grounding adapter.
NOTICE: The locations for the supply shut-off, electrical outlet, and docking station cord are suggested
locations. Make sure all installations adhere to applicable codes and standards.
IMPORTANT! Locating the supply stop behind the toilet will make it difficult to remove the back panel.
It may be necessary to remove the toilet to service items behind the back panel if the supply stop extends
more than 3" (76 mm) from the wall.
IMPORTANT! Do not install any items behind the toilet that will interfere with the cover when it is
raised. All decorative items should be at least 37" (940 mm) high to allow clearance for the cover.
The remote docking station is equipped with a 15' (4.5 m) power cord. The station mounting
location shown for the docking station is ADA compliant.
The supplied power cord is 56" (1422 mm) in length. Install the GFCI or RCD protected outlet
within 56" (1422 mm) of the toilet location.
The toilet is equipped with a motion sensor to automatically open the cover when movement is
sensed. This sensor has a maximum range of 51-1/2" (1300 mm). Sensitivity can be adjusted or
turned off using the User Interface.
The toilet is equipped with a sensor to automatically open the seat when the light is interrupted.
The sensor is located on the right side of the toilet. This sensor has a maximum range of 8" (203
mm). Keep this area free of obstructions.
Kohler Co.
14-1/2"
(368 mm)
25-3/4"
(654 mm)
Docking Station
5-15/16"
(151 mm)
2-1/4"
4-1/16"
(57 mm)
(104 mm)
41" (1041 mm) -
15-5/8"
(397 mm)
C
C L Of Outlet
10-13/16" (275 mm)
Optional Supply
1/2" OD Compression
Outlet Thread
13-5/8"
(346 mm)
1/2" OD
Compression
66" (1676 mm)
Outlet Thread
6"
(152 mm)
5
Front of Bowl
4-3/4" (121 mm)
Ø 2-5/8"
(67 mm)
12"
(305 mm)
Power Cord
Reaches
56" (1422 mm)
8" (203 mm)
2" (51 mm)
25-1/4"
(641 mm)
Finished
Wall
17-7/8"
(454 mm)
Outlet
1132336-2-D