2. Checking the Height Accuracy of the cross created by the
longitudinal (#4) and horizontal lines.
(Up and down deviation)
1) Set up the laser on a table or on the floor between 3 walls A, B
and C. The distance between A and B should be approximately 5
meters.
2) Position the laser level approximately 0.5 meters from wall A and 2
meters from wall C.
3) Unlock the pendulum and press the Beam Selector (a) twice, to
project all 3 lasers beams.
4) Direct the cross lines of the horizontal beam and the forward
vertical beam (#4) towards wall A.
5) Repeat the previous marking procedures from paragraph 5 - 15
3. Checking the Accuracy of the forward Vertical beam (#4).
1) Hang an approximately 3 meter long plumb line on a wall.
2) After the plumb line has settled, mark point a1 on the wall behind
the plumb line, near the plumb cone. (see figure # 5).