Water Connection (Add-On Equipment) - Salvis Marmite 800 Plus Instructions D'installation Et Mode D'emploi

Sauteuse polyvalente
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

7.4

Water connection (add-on equipment)

Screws
Hose inlet
Panel
D Observe the regional conditions and the
"Technical Rules for Drinking Water Installa-
tions DIN 1988"!
D Rinse through on-site water pipes and sup-
ply hoses before connecting.
D The appliance must be connected to an ea-
sily accessible water stopcock.
D Connect to a hot water supply max. 50°C.
D Water pressure: min. 200 kPa (2 bar) dyna-
mic, max. 600 kPa (6 bar) static.
D In order to compensate for pressure fluctua-
tions and to avoid spraying when filling, con-
nect a pressure reducing valve in series on-
site and set to 200 kPa.
D If the water hardness is greater than
10° dKH, we recommend installing a water
softening device in the water supply.
D There must be no connecting pipes made
from galvanized iron or similar material bet-
ween the water softening device and the ap-
pliance, otherwise there is a risk of rust for-
ming!
D Observe the installation and user manuals
for the connected water softening device.
D The supply hose may not be kinked or crus-
hed.
D Check all connections are water-tight.
en