The following times can be considered as an indication for
the accu life time:
Measurement interval (minutes) Measurement period (accu days)
1
5
10
30
60
The program allows you to read from and write to the device; and
E
also save the configuration to a file.
N
The tool creates an xml file that is stored on the SD card.
G
This configuration file (located at /config/config.xml of the
L
SD card) has the following elements:
I
Element
S
config
interval
H
device
The configuration file for device 0x9000, measuring every minute
would look like this:
<?xml version="1.0" encoding="UTF-8"?>
<config>
<interval>60</interval>
<device>0</device>
</config>
Initially the SD card must be formatted (FAT32). Often cards which
already have been formatted are delivered, but if needed you can
also format a card by PC-software in a card reader. The Software will
create a directory 'log' automatically as a location to store the log-
ging files. At the log-directory the system will generate a text file for
each sensor and each month.
Description
root element
measurement interval specified in seconds
(min 30 secs, max 3600 secs)
The device number in decimal. The firmware
will adjust the number such that it is within the
range 0x9000 and 0xa000