Design / Specifications; Safety Instructions - Victron energy Impulse S12 Manuel

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

2. DESIGN / SPECIFICA TIONS
Primary voltage
Secondary nominal voltage
Secondary maximum voltage : 35 V
Secondary current
max. 16 A for Impulse S 16 *)
Battery type
Battery capacity
Impulse S12
Impulse S16
120 Ah
Protective devices
Input power
Efficiency
Ambient temperature
Dimensions cabinet
Safety class
International Protection class : IP 21
Overall weight
Transport and storage
Ambient temperature storage : -15° C ... +50° C.
Relative air humidity max.
(non condensing)
*) can be set by the supplier/dealer

3. SAFETY INSTRUCTIONS

Carefully read the manual and the Safety Instructions.
The IMPULSE S should never be exposed to the rain or be stored in a humid room.
The IMPULSE S is exclusively for indoor application.
Explosion hazard!
Avoid sparking or fire in the immediate environment of the battery.
4
: 230 Vac - 50/60 Hz - 1-phase
: 12V or 24V *)
: max. 12 A for Impulse S 12 *)
: Lead acid: Gel/W et/AGM *)
: *)
Min.
Max.
(in order to charge
80% capacity
Within 8 hours)
80 Ah
125 Ah
165 Ah
: - protected against reversed polarity
- protected against high temperatures
450 W with Impulse S12
600 W with Impulse S16
: min. 80% (at full load)
: 0 ° C to +40 ° C
: Height 80 x W idth 180 x Depth 220 mm
: II
: 1.6 kg
: 90 %

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Impulse s16

Table des Matières