Fan Speed Button (Speed); Sleep Mode Button (Sleep); Dehumidification Button (Dehum) And Connection Of The Hose; Remote Control - Noaton AC 5109 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 63

Fan speed button (SPEED)

By pressing this button you switch between low (LOW) and high (HIGH) fan speeds. At the same time, a diode
will light up on the control panel beside the relevant speed. This option to change speeds is switched off in the
dehumidification (DEHUM) and sleep (SLEEP) modes.

Sleep mode button (SLEEP)

In the cooling (COOL) mode you can select sleep mode. Because of the lower noise level the fan runs at a lower
speed and during the first two hours of the target temperature will be automatically raised by one degree
Celsius every hour.

Dehumidification button (DEHUM) and connection of the hose

The air conditioner will operate at the lower fan revolutions and dry out the air in the room, provided room
temperature remains above 15°C. In this mode it is not possible to set a required temperature or change the
fan speed. If the room temperature is lower than 15°C, the compressor will switch itself off and
dehumidification will stop.
In this mode it is necessary to attach the hose for releasing water – remove the plug from the lower part of the
appliance and attach the hose with a 16 mm diameter (included in the pack). The other end of the hose should
either drain into a suitable vessel or directly to a drain. The hose should be set at the minimum incline in order
for the condensate to drain out properly.
Once dehumidification is complete, disconnect the hose from the machine and – with a gentle tipping motion
towards the outflow – pour out the remaining water from the air conditioner (it is a good idea to place a
shallow vessel or plate below the outflow); finally, replace the plug onto to the outflow.
Switch off the dehumidification mode by changing to another mode using the MODE button.

Remote control

Switch the
appliance on/off
Increasing temperature/timer
value
Decreasing
temperature/timer value
Two-way timer
(to set a delayed start or
switch-off, see the section
Timer button)
40
Choice of mode
(MODE)
Change of fan speed
Sleep mode