3.5.2 Connection of E-pump to LiqTec®
Connection terminals on E-pump:
2 (Start/Stop) and 3 (GND) 3
Connection of E-pump to LiqTec
Fig. 9

3.6 Bus connection cable

3.6.1 New installations
For the bus connection, use a screened 3-core cable with a
conductor cross-section of 28-16 AWG.
If the pump is connected to a unit with a cable clamp which is
identical to the one on the pump, connect the screen to this
cable clamp.
If the unit has no cable clamp as shown in fig. 10, leave the
screen unconnected at this end.
A
1
2
Y
3
B
Fig. 10 Connection with screened 3-core cable
10
Dry-running sensor
Set to automatic resetting
2
Pump
A
1
2
Y
3
B
Jumper cable
1 x 200-240 VAC
or
1 X 80-130 VAC
3.6.2 Replacing an existing pump
If a screened 2-core cable is used in the existing installation,
connect it as shown in fig. 11.
A
1
Y
2
B
Fig. 11 Connection with screened 2-core cable
If a screened 3-core cable is used in the existing installation,
follow the instructions in section 3.6.1 New installations.
Pump
A
1
Y
2
B