Important Information 4 2. Informazioni Importanti - Austroflamm Wien Manuel D'instructions

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

english
1.
TECHNICAL DATA
TECHNICAL DATA
Height
Width
Depth
Weight
Weight with ceramic shell
Flue pipe outlet diameter
Nominal thermal output (EN
Maximum thermal capacity
13240)
Room heating capacity (depending
on building insulation)
2.
IMPORTANT INFORMATION
The installation and operation information given here is of
. National and European standards, local
general nature
and building regulations as well as fire prevention laws
must be observed during the operation of the stove.
General safety instructions for the
operation of your stove
Thoroughly read the entire manual before starting up
your stove and observe the caution notices.
Your heating unit may not be moved without
approved means of transport with sufficient load-bearing
capacity.
Your heating unit is not suitable to be used as a
stand or as a ladder.
Please keep in mind that
your stove's surface heats up
considerably during operation.
We
therefore
recommend
wearing a safety mitten when
operating your stove.
Attention – stove varnish is no rust prevention!
Make your children aware of this particular danger
and keep them at a distance from the heating unit
whenever it is in operation.
Only burn approved fuels and materials listed in the
chapter "Clean Burning".
The burning or placing of flammable or explosive
materials, such as empty spray cans and such like into
the firebox as well as the storage of such materials in the
immediate vicinity of your heating unit is strictly forbidden
due the danger of explosion.
Do not wear loose or flammable clothing when
adding fuel to the fire.
Placing non-heat-resistant objects on the heating
unit or in the vicinity of the heating unit is forbidden.
5
Exhaust values for multiple use of the chimney in
accordance with DIN 4705, Part 3 and for the
calculation of the chimney measurements in
709 mm
accordance with DIN 4705, Part 2
690 mm
Fluegas mass flow
582 mm
160 kg
Fluegas temperature
-----------
Minimum feed
150 mm
pressure
6,5 kW
Nominal thermal output
9 kW
82 – 210 m³
hung up to dry must be kept at a safe distance from the
stove because of the danger of fire.
heating.
forbidden to use flammable or explosive materials in the
same or an adjacent room to the one in which your
heating unit is located
door closed.
stove must be closed, if the appliance is out of use.
Setting up your stove
Required safety distances
distances – see name plate - in Fig. 2))
a > 120 cm
b > 55 cm left, 65 cm right
c > 50 cm *)
(a – toward the front in the radiated area)
(b – to the side)
(c – to the back)
*) When using the rear protection plate, the safety distance
reduces to 20 cm
Make sure that the room in which the stove is set up
has at least one door or window into the outside or is
directly adjacent to such a room. Other fireplaces and
extractor hoods must not be operated in the same
room as the stove.
Floor load capacity
Make sure that the load capacity of the supporting
construction is sufficient to carry the weight of the entire
unit
, before the heating unit is installed.
closed
closed
closed
at 0.8 times
n. ther. outp.
Do not lay laundry onto the stove for drying. Laundry
The woodstove Wien is not suitable for long term
During the operation of
.
The appliance must be operated with the stove
The stove door and all fittings for adjusting the
Wien
6,1 g/s
314 °C
11 Pa
9 Pa
your heating unit it is
(Minimum

Publicité

Table des Matières
loading

Table des Matières