Ingersoll Rand UP6 15 Mode D'emploi page 17

Masquer les pouces Voir aussi pour UP6 15:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

KEY
CON
Controller, INTELLISYS
CPT
Transformer, control
EDV
Valve, electric drain
E–STOP
Button, emergency stop
FU
Fuse
1M
Contactor (main)
2M
Contactor (delta)
OL
Overload, motor starter
1SV
Valve, solenoid (load) N.C
3SV
Valve, solenoid (blowdown) N.O
10SV
Valve, solenoid (line / sump) N.C
RST
Remote start
(Optional)
RSP
Remote stop
(Optional)
CFO
Common fault output
PORO
Power out restart (Optional)
2ATT
Temperature sensor
3APT
Pressure sensor
1S
Contactor (wye / star)
http:/air.ingersollrand.com
INTELLISYS OPTION
NOTES
1.
Approved fused disconnect or circuit breaker per code
requirements must be provided by customer.
2.
Dashed lines represent wiring by customer.
3.
Sizing of electrical components not supplied by Ingersoll Rand is
the responsibility of the customer and should be done in
accordance with the information on the compressor data plate
and local electrical codes.
4.
Unit will not restart automaticlly after power outage, except with
additional PORO option.
5.
Circuit shown in normal position de–energized.
6.
All wiring to be in accordance with local codes.
7.
Blue – 16 Volts AC
15
UP6 15, UP6 20, UP6 25, UP6 30

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Up6 20Up6 25Up6 30

Table des Matières