4.2.3
Alternating voltages at low impedance (V
AC LowZ True RMS)
The input impedance is 270k .
A low input impedance serves to eliminate the effects of
interference voltages due to the supply network, and makes it
possible to measure an AC voltage with a minimum of error.
Range
Resolution
Uncertainty (±)
6 V
0,001 V
60 V
0,01 V
40 Hz à 60 Hz
2 % + 10 cts
600 V
0,1 V
1000 V *
1 V
* According to safety rules, 1000V range is limited to 600V.
4.2.4
Frequency (V AC or A AC)
Range
Resolution
Uncertainty (±)
10 to 3000 Hz
0.01 Hz
4.2.5
Duty Cycle
Range
Resolution
Uncertainty (±)
0.1 to 99.9 %
0.1 %
1.2 % + 2 cts
4.2.6
Resistance
Range
Resolution
Uncertainty (±)
600
0.1
2 % + 2 cts
6 k
0.001 k
60 k
0.01 k
0.3 % + 4 cts
600 k
0.1 k
6 M
0.001 M
60 M
0.01 M
0.5 % + 20 cts
51 - 138
Sensitivity
0.5 %
15 V RMS
Frequency
5 Hz to 150 kHz