Electrical Service

GENERAL

!
All wiring must conform to local, state and national
codes.

VOLTAGE

The maximum allowable voltage variation is ± 10% of
the rated voltage on the ice machine model/serial
number plate at start-up (when the electrical load is
highest).
The 115/1/60 ice machines are factory pre-wired with a
8' power cord, and NEMA 5-15P-plug configuration.
The 208-230/1/60 and 230/50/1 ice machines are
factory pre-wired with a 8' power cord only, no plug is
supplied.

FUSE/CIRCUIT BREAKER

A separate fuse/circuit breaker must be provided for
each ice machine. Circuit breakers must be H.A.C.R.
rated (does not apply in Canada).
!
The ice machine must be grounded in accordance
with national and local electrical codes.

Q130/Q170/Q210/Q270 ICE MACHINE

Ice Machine
Q130
208-230/1/60
Q170
Q210
208-230/1/60
QP0210A
Q270
Danfoss
208-230/1/60
Compressor
QP0270A
Q270
Tecumseh
208-230/1/60
Compressor
* Indicates preliminary data
8
Warning
Warning
Voltage
Phase
Maximum Fuse/
Circuit Breaker
Cycle
115/1/60
15
15
230/1/50
15
115/1/60
15
115/1/60
15
15
230/1/50
15
230/1/50
15
115/1/60
15
15
230/1/50
15
230/1/50
15
115/1/60
15
15
230/1/50
15

TOTAL CIRCUIT AMPACITY

The total circuit ampacity is used to help select the wire
size of the electrical supply.
The wire size (or gauge) is also dependent upon
location, materials used, length of run, etc., so it must be
determined by a qualified electrician.

GROUND FAULT CIRCUIT INTERRUPTER

Ground Fault Circuit Interrupter (GFCI/GFI) protection is
a system that shuts down the electric circuit (opens it)
when it senses an unexpected loss of power,
presumably to ground. Manitowoc Ice, Inc. does not
recommend the use of a GFCI/GFI circuit protection with
our equipment. If code requires the use of a GFCI/GFI
then you must follow the local code. The circuit must be
dedicated, sized properly and there must be a panel
GFCI/GFI breaker. We do not recommend GFCI/GFI
outlets as they are known for more intermittent nuisance
trips than panel breakers.
PERSONAL INJURY POTENTIAL
If the supply cord is damaged, do not operate the
equipment until the cord is replaced by a service
agent or similarly qualified person.
Air-Cooled
Total Amps
7.0
3.1
3.0
7.2
6.5
3.6
3.6
3.6*
10.7
5.2
5.2
5.2*
8.5
4.5
4.5
!
Warning
Water Cooled
Maximum Fuse/
Total Amps
Circuit Breaker
15
15
15
--
15
15
15
15
15
15
N/A
15
15
15
Part Number 040002380 9/12
Section 2
6.3
2.6
2.5
--
6.1
3.1
3.1
9.9
4.7
4.7
N/A
7.7
4.0
4.0

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Undercounter q170 serieUndercounter q210 serieUndercounter q270 serieQ130Q170Q210 ... Afficher tout

Table des Matières