- If the burner does not ignite on propane gas after two or three attempts, stop and consult your local dealer or an authorized
Norcold Service Center.

Set the controls to automatic mode operation:

- Push the ON / OFF button to turn the refrigerator on.
- Push and hold the MODE button until the letters "AU" show in the center display and then release.
- If 120 volts AC is available to the refrigerator:
- The letters "AU" and then "AC" show in the center display.
- After ten seconds, the "AU" and then "AC" go off and only a green power ON light remains.
- This means that the refrigerator is operating on AC electric.
- If 120 volts AC is not available to the refrigerator:
- The letters "AU" and then "AC" show in the center display.
- After five seconds, the "AU" and then "LP" show in the center display.
- After ten seconds, the "AU" and the "LP" go off and only a green power ON light remains.
- This means that the refrigerator is operating on propane gas.
- If neither 120 volts AC nor propane gas is available to the refrigerator:
- The fault codes "no" "AC" and then "no" "FL" show in the center display and an audible alarm sounds.
If an energy source is available to the refrigerator, but is not operating correctly:
- A fault code shows in the center display.
- The refrigerator controls try to change to a less efficient energy source.
- If a less efficient energy source is not available:
- An audible alarm starts.
- A fault code shows in the center display.
- Refer to the "Fault Codes" section of this manual.

Set the controls to manual mode operation:

- Push the ON / OFF button to turn the refrigerator on.
- Push and hold the MODE button until the letters " AC" show in the center display and then release.
- After ten seconds, the "AC" goes off and only a green power ON light remains.
- Push and hold the MODE button until the letters "LP" show in the center display and then release.
- After ten seconds, the "LP" goes off and only a green power ON light remains.
If the energy source is interrupted:
- A fault code shows in the center display.
- Refer to the "Fault Codes" section of this manual.