Operational control

(See illustration on fold-out page)
(1) Mains switch for starting (I = ON / 0 = OFF)
(2) Overload indicator shining red
(3) Two colored status display
green = alternating voltage OK
red
= over-/ undervoltage
(4) Euro-socket for safety class 2 – connected device
Model 160 W / 220 W = one socket
Model 500 W = 3 sockets
Model 1000 W = one socket
Model 1700 W = 2 sockets
(5) Ventilation holes for built-in ventilator (not in 160W converter)
(6) DC-connection wire
(7) Cigarette lighter plug (only Model 160 W and 220 W)
(8) DC-input fuse (fuses vary according to the model)
(9) Shock-proof plug for connected device of safety class 1 and 2 (only in model
1000 W and 1700 W)
(10) Screw terminal "negative pole" (-)
(11) Screw terminal "positive pole" (+)

Safety instructions

Any claims for guarantee will become invalid in the event of dam-
age that results from the non-observance of the operating manu-
al. We do not accept responsibilty for such damage. Nor do we
accept responsibility for damage to property or for personal
injuries caused by improper use or non-observance of safety
instructions. Guarantees will not be accepted in any such case.
• This device has left our factory in a technically reliable, flawless condition.
In order to preserve this condition and to ensure safe operation we kindly request
the user to respect the safety instructions and warning notes (Warning!" and
"Note!") contained in this operating manual. The following symbols should be not-
ed:
16
All manuals and user guides at all-guides.com
Changing the fuse
The voltage converters are protected on the DC-supply side via customary flat fuses
(FKS-motor fuses) against short-circuits or overloads.
If the voltage converter does not switch on any more (operation switch and status
indicator do not light), so it is probable that a DC-input fuse(s) is/are defective.
To change the fuse(s) proceed as followed:
• Switch the voltage converter off and disconnect all connected devices from the
converter.
• Remove all fuses (8) from the mounting and replace them with new fuses with the
same safety value (See technical data)
• While changing the fuses, make sure that the flat fuses sit well and securely.
Warning! Only fuses of the prescribed value can be used as replace-
ment. Bridging the fuse holder or using mended fuses is not allowed.
Contact inspection
Regularly inspect the firmness of the screw contacts to avoid contact resistance
(loss of power).
The inspection intervals depend on the environmental conditions:
- Device and wire are not exposed to mechanical stress
- Device and wire are exposed to slight stress
Fixing faults
With the power converter you have acquired a reliable and falt free product.
However, problems and faults can occur.
This is why we would like to explain to you how you can solve these problems:
Please observe the security measures!
approx. once a year,
approx. every 3 – 4 months.